TURBO MODE: If desired the set up time can be shortened by manually overriding the automatic “crawl”speed in steps 1, 2, 3 shown on page 24. This is done by pressing and holding the TEST button. The speed increases to FULL speed while the button is depressed.

NB. Do not run the gate into the end stops at full speed.

CP80

L1 L2

control card

 

TEST

 

STATUS

 

SET

CP80

74

control card

L1 L2

 

TEST

 

STATUS

 

SET

EXIT GATE LIMITS ROUTINE (D3/D5 ONLY)

-After the gate stops at the required pedestrian position (see step 6 on page 24) ie either at the automatic minimum or the manually over-ridden position, press the TEST button for a moment and release.

-L2 will illuminate when TEST button is released.

-Remove SET link and position as shown above, 74 , to exit programming unless proceeding to other menus.

NB. If automatic routine does not complete (indicated by STATUS flashing 5 times & L2 illuminating) then it may be necessary to set collision sensitivity to MED or LOW (see page 28)

START MANUAL GATE LIMITS ROUTINE

A5 ONLY (PAGE 26 & 27)

25

Page 27