TABLE 3

 

MAIN

UNIT OF

 

 

MENU

MEASURE

 

 

 

 

 

 

 

Each flash

 

 

No of times of STATUS

 

 

L1 flashes

represents

 

 

 

 

 

 

 

FACTORY

 

 

 

DEFAULTS

NORMAL AUTOCLOSE

3

1 SEC

15 SEC

 

 

 

 

PEDESTRIAN AUTOCLOSE

5

1 SEC

5 SEC

 

 

 

 

COURTESY LIGHT

6

10 SEC

12x10 SEC

 

 

 

 

AUTOCLOSE OVERRIDE

8

1 SEC

3 SEC

 

 

 

 

PREFLASH TIME

11

1 SEC

5 SEC

 

 

 

 

COLLISION COUNTER

12

1 COUNT

4 COUNTS

 

 

 

 

CRAWL DISTANCE (D3/D5)

13

350 MM

1x350mm

COAST MODE (A5)

13

10 MM

30mm

THE CRAWL DISTANCE IS A LENGTH OF TRAVEL WHICH ALLOWS THE GATE TO SLOW DOWN BEFORE REACHING THE END STOP. FOR HEAVIER GATES WITH LESS FRICTION, THE CRAWL DISTANCE MAY HAVE TO BE INCREASED. WHEN INCREASING THE CRAWL DISTANCE, THE POSITION OF THE ORIGIN MARKER (ITEM 66 PAGE 15) MUST BE MOVED.

 

CRAWL

STATUS FLASH

DISTANCE BETWEEN

 

DISTANCE

COUNT

MARKER AND PINION

DEFAULT

350mm

1

500mm

 

 

 

 

700mm

2

750mm

1050mm

3

1100mm

TURBO MODE: TO SPEED UP THE COUNTING WHILE SELECTING MAIN MENU ITEMS TEMPORARILY CONNECT “PED” TERMINAL TO “COM”

30

Page 32
Image 32
Centurion CP72SR5 installation manual Main Unit Menu Measure