CP80/CP81 | L1 L2 | |
control card | ||
TEST | ||
| ||
| STATUS | |
| SET |
SETTING GATE LIMITS (continued)
NB. Ensure you follow the correct procedure!
The procedure for setting D3/D5 and A5 motors is DIFFERENT. The A5 limits have to be set manually (see page 25 and 26), while the D3/D5 motors set their limits automatically (see page 21 to 23).
D3/D5 ONLY (PAGE 23, 24, 25)
-Press the TEST pushbutton while monitoring LED L1.
-When L1 flashes once, release TEST pushbutton. L2 will go out,
L1 will continue to flash once per second. Controller is now in MENU 1 which sets gate limits.
NB. Understand the procedure detailed on page 24 before continuing.
The controller is about to perform the fully automatic setup routine.
CP80/CP81 | L1 | L2 | |
control card | |||
TEST | |||
| |||
| STATUS | ||
|
| SET |
START AUTOMATED GATE LIMITS ROUTINE
-Press TEST pushbutton until STATUS LED illuminates.
-AUTOMATIC set up routine (described on page 24) starts as soon as TEST button is released.
23