NOTES:

The gate with the longer travel span (opening) must be set as the primary gate (GATE 1).

If one gate is overlapping the other, the gate that is overlapping must be connected to GATE 1 so it will start moving before the other gate; gate 2 may need to be closed first if there is overlap or a gate lock is being used.

The programming can be exited at any time by pressing the RESET button. Programming times-out automatically after 60 seconds of inactivity.

DUAL GATE (LEFT-SIDE PRIMARY OPERATOR)

PROGRAM OPEN

With the gate in the CLOSED position, press the LEARN LIMITS button (SET OPEN LIMIT LED will blink).

DUAL GATE (RIGHT-SIDE PRIMARY OPERATOR) PROGRAM OPEN

With the gate in the CLOSED position, press the LEARN LIMITS button (SET OPEN LIMIT LED will blink).

SET

OPEN LIMIT

Press the GATE 1 right button to open the left operator.

DIAGNOSTIC

GATE 1

SET

CLOSE

Press the GATE 2 right button to move the right operator into the OPEN position.

SET

CLOSELIMIT LIMIT

GATE 2

FORCE

Press the LEARN LIMITS button. Control board will beep.

PROGRAM CLOSE

When the SET CLOSE LIMITS LED blinks, press the GATE 2 left button to close the right operator.

SET

CLOSELIMIT LIMIT

GATE 2

FORCE

Press the GATE 1 left button to close the left operator.

DIAGNOSTIC

GATE 1

SET

CLOS

Press the LEARN LIMITS button.

Press the GATE 1 left button to open the right operator.

DIAGNOSTIC

GATE 1

SET

CLOS

Press the GATE 2 left button to move the left operator into the OPEN position.

SET

CLOSELIMIT LIMIT

GATE 2

FORCE

Press the LEARN LIMITS button. Control board will beep.

PROGRAM CLOSE

When the SET CLOSE LIMITS LED blinks, press the GATE 2 right button to close the left operator.

SET

CLOSELIMIT LIMIT

GATE 2

FORCE

Press the GATE 1 right button to close the right operator.

DIAGNOSTIC

GATE 1

SET

CLOSE

Press the LEARN LIMITS button.

The control board beeps and the SET OPEN LIMIT and SET CLOSE LIMIT LEDs stop blinking, programming is now complete. (If the SET OPEN LIMIT LED continues to blink, repeat programming. If the problem continues, see Troubleshooting section.)

Test the limits by pressing the SBC to open and close the gate.

Programming