8 CONNECT BATTERIES

The batteries are charged in circuit by using the solar panel (provided).

Locate the two white battery plugs on the left-hand side of the control box. Connect the plug from the battery to connector on the control board.

NOTES: Batteries will degrade over time depending on temperature and usage. For best performance, the batteries should be changed every 3 years.

Batteries do not perform well in extremely cold temperatures.

To reduce the risk of FIRE or INJURY to persons use ONLY LiftMaster part 27-NP712 for replacement batteries.

 

C1Ø1

 

R182

 

 

 

 

 

 

P1

 

 

 

 

 

 

J19

 

 

 

 

 

D36

 

 

 

 

 

 

 

 

J18

 

SOL

 

 

 

 

 

 

 

 

 

 

GND

 

 

 

 

L1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MAGR

 

 

K5

 

 

 

 

 

U4

LOCK

 

D42

 

F12

 

ON

OFF

C75

 

 

Z1

R2

 

 

LEARN

LOCK /

 

 

 

 

 

 

 

 

XMITTER

BIPART DELAY

 

 

 

 

 

 

 

 

 

 

 

GATE 1

R1

 

 

D1Ø

 

 

 

C7Ø

 

 

 

 

 

 

 

 

 

 

 

 

BR

 

 

 

 

 

 

C71

 

 

 

 

 

 

 

 

K2

 

C72

 

 

 

GR

 

 

 

 

 

C73

 

 

 

WH

 

 

 

 

 

 

18

 

 

YL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BL

 

 

 

 

 

 

 

GATE 1

 

 

RD

 

 

 

 

 

 

 

 

 

Battery Connectors

 

 

 

 

SET

 

SET

LEARN

 

 

 

 

 

 

K1

OPEN

 

CLOSE

 

 

 

 

 

 

LIMIT

 

LIMIT

LIMITS

 

 

 

 

 

 

Q9

 

 

 

GATE 2

TIMER

 

 

 

 

 

 

 

 

 

RUNNING

C66

C65

 

C68

 

Z22

 

Q6

 

C33

 

Q12

F11

R93

 

Q1

CTRL PWR

OVLD

Control Board

 

24V

R9Ø

 

 

 

 

 

 

BR R1ØØ

R1Ø1

 

 

 

 

 

 

GR

 

 

 

 

 

 

Battery Connection

WH

 

 

K4

 

 

 

 

YL

 

 

 

 

 

OFF

 

 

 

 

 

 

 

 

BL

 

 

 

 

D44

 

 

RD

 

 

K3

 

D8

 

 

 

 

 

 

 

 

GATE 2

 

 

 

 

D4

 

 

D16

 

Q22

 

 

 

 

 

 

 

 

 

 

 

 

F9

 

R196

 

R9

 

 

J21

 

J23J24

 

 

D1

R329

 

 

F3

 

R27

 

F1

 

 

 

 

 

 

30

AØ3

AØ3

30

C64

R22

 

 

 

32V

32V

 

U2

DB1

 

 

 

 

 

 

Board Connectors

ØJ2

MAX

 

R186

OFF

MAX

 

 

C12

 

 

 

 

Z4

F7

 

 

 

 

 

 

 

 

D2

C13

 

 

 

 

D129

C11

JU1

 

C69

F2

R42Ø

MOV1

 

 

R423

 

 

 

 

K6

 

 

 

JU2

 

 

 

 

 

JU1

 

 

 

OPEN

 

SINGLE BUTTON

 

 

RESET

 

 

STOP

 

 

COM

 

 

COM

 

 

 

R184

CHGR

 

 

OVLD

 

 

AC PWR

 

 

/SOLAR

C2

 

 

R4

MOV2

Solar Panel Installation

32