OPERATION AND MAINTENANCE

IMPORTANT SAFETY INSTRUCTIONS

WARNING

To reduce the risk of SEVERE INJURY or DEATH:

1.READ AND FOLLOW ALL INSTRUCTIONS.

2.NEVER let children operate or play with gate controls. Keep the remote control away from children.

3.ALWAYS keep people and objects away from the gate. NO ONE SHOULD CROSS THE PATH OF THE MOVING GATE.

4.Test the gate operator monthly. The gate MUST reverse on contact with a rigid object or stop when an object activates the non-contact sensors. After adjusting the force or the limit of travel, retest the gate operator. Failure to adjust and retest the gate operator properly can increase the risk of INJURY or DEATH.

USING YOUR GATE OPERATOR

Your operator will operate with up to forty-nine Security® remote controls and one Security® Keyless Entry System. If you purchase a new remote, or if you wish to deactivate any remote, follow the instructions in the Programming section.

Activate your operator with any of the following:

The hand-held Remote Control (See Accessories): Hold the large push button down until the gate starts to move.

The Keyless Entry (See Accessories): If provided with your gate operator, it must be programmed before use. See Programming.

When the operator is activated (with the safety sensors correctly installed and aligned)

1.If open, the gate will close. If closed, it will open.

2.If the gate has been stopped in a partially open position, it will close.

3.If obstructed while closing, the gate will stop and reverse direction for approximately 2 seconds and then stop. The next command will open the gate.

4.If obstructed while opening, the gate will stop and reverse direction for approximately 2 seconds and then stop. The next command will close the gate.

The operator alarm will sound under the following condition: If gate encounters two consecutive obstructions, before reaching the open or close limit, the operator will stop, the alarm will sound (up to 5 minutes) and the control board will require resetting. Reset the control board by pressing the “Reset Button” located on the outside of

the control box. No commands at this time will operate gate. After the operator is reset, normal functions will be available.

5.Use the emergency release ONLY when the gate is not moving.

6.KEEP GATES PROPERLY MAINTAINED. Read the owner’s manual. Have a qualified service person make repairs to gate hardware.

7.The entrance is for vehicles ONLY. Pedestrians MUST use separate entrance.

8.Disconnect ALL power BEFORE performing ANY maintenance.

9.SAVE THESE INSTRUCTIONS.

The Timer-To-Close (TTC) Feature comes from the factory in the OFF setting.

The “TIMER RUNNING LED” will flash once for every second of adjusted time. The gate(s) must fully open for the timer feature to be active and close the gate(s). Any radio command or pressing the single button on the control board prior to the TCC time expiring will close the gate. The TTC is reset by any signals from the loops, close edges, and close safety sensors (IR’s).

Party Mode: If the Timer-to-Close feature is enabled and you would like the gate to remain open, simply push the reset button (located on the outside of the control box).

To set party mode: open the gate fully, then press the reset button. The next command given by remote control or SBC on the control board will close the gate and return the operator to normal operation.

Sleep Mode (Battery Conservation): The operator enters sleep mode 10 seconds after the last command is given. The diagnostic LED will blink in this mode. The safety sensors (photo eyes) indicator LEDs will not be on. The next command given will return the operator to normal operation.

Reset Button: The reset button can be used to set the operator into party mode and to reset the alarm after an obstruction. The diagnostic LED can be reset by holding the reset button for 1 to 2 seconds.

RESET

RESET

Reset Button

37

Operation and Maintenance