PROGRAMMING

Program Limits

The limits are internal settings that indicate when the gates are in the fully open position and the fully closed position. For proper functionality, the limits must be programmed during the installation process. The programming uses a combination of buttons on the control board.

The specifi c buttons used for programming depends on which side of the gate the control box is mounted and how many operators the installation includes. Refer to pages 11 and 13 to determine if the gate is Left- or Right-handed.

If a mistake is made during programming press the RESET button on the outside of the control box to start over.

SINGLE ARM LEFT-HAND SIDE

SINGLE ARM RIGHT-HAND SIDE

NOTE: The programming can be exited at any time by pressing the RESET button. The programming times-out automatically after 60 seconds of inactivity.

PROGRAM OPEN

With the gate in the CLOSED position, press the LEARN LIMITS button (SET OPEN LIMIT LED will blink).

LEARN LIMITS button

SET

OPEN

LIMIT

RESETET

BUTTON

BUTTON

Press the Gate 1 right button to move gate to the desired OPEN position. When gate is in the desired position, press the LEARN LIMITS button again. Control board will beep.

DIAGNOSTIC

GATE 1

SET

CLOSE

PROGRAM CLOSE

Press the Gate 1 left button to move gate to the desired CLOSED position. When gate is in the desired closed position, press the LEARN LIMITS button again.

DIAGNOSTIC

GATE 1

SET

CLOS

PROGRAM OPEN

With the gate in the CLOSED position, press the LEARN LIMITS button (SET OPEN LIMIT LED will blink).

LEARN LIMITS button

SET

OPEN

LIMIT

RESET

BUTTON

Press the Gate 1 left button to move gate to the desired OPEN position. When gate is in the desired position, press the LEARN LIMITS button again. Control board will beep.

DIAGNOSTIC

GATE 1

SET

CLOS

PROGRAM CLOSE

When the SET CLOSE LIMIT LED blinks, press the Gate 1 right button. When gate is in the desired closed position, press the LEARN LIMITS button.

DIAGNOSTIC

GATE 1

SET

CLOSE

The control board beeps and the SET OPEN LIMIT and SET CLOSE LIMIT LEDs stop blinking, programming is now complete. (If the SET OPEN LIMIT LED continues to blink, repeat programming. If the problem continues, see Troubleshooting section.)

Test the limits by pressing the SBC to open and close the gate.

33

Programming