Technical Information
-26- Legend 300E Spot User Manual Rev. 01g
Error Messages
Message Cause(s) Actio n(s)
Lamp Startup Fail
The lamp has not start ed after being struck
· Check lamp
· Check lamp socket and wiring
·
Check ballast and igniter
Temperature Sense
Error No communication with t emperature
sensor · Check sensor wiri ng
· Check sensor integrity
· Check control board
Lamp too Hot Low
Power
Ambient temperature hi gher than 105º C;
lamp in low power for s afety · Check f ans
· Check fan wiring
·
Clean vents
Lamp Too Hot Power Off
Ambient temperature hi gher than 110º C;
lamp off f or safet y ·
Check fan s
· Check fan wiring
· Clean vents
Maintenance Fixture
Fixture Maintenance timer exp ir ed ·
Proceed with maintenance and r es et ti mer
Lamp On Over 700 Hour
Lamp change is overdue ·
Change lamp
Memory Initial Fail
Memory chip error ·
Change main board
CPU-B Error
CPU-C Error
CPU-D Error
No communication with auxiliary CPU
· Check sensors wiring an d position
· Check stepper motor, bel t, and driver board
· Check control boards
Pan Reset Error
Pan Encode Error
Tilt Reset Error
Tilt Encode Error
Moving head failed goin g to home position
after power up or fixtur e reset · Check moving h ead’s free movement
· Check sensors’ wiring and positi on
· Check stepper motor, bel t, and driver board
· Check the correspondin g control board
· Check main control boar d
Shutter Reset Fail
Dimmer Reset Fail
Color Reset Fail
Cyan Reset Fail
Magenta Reset Fail
Yellow Reset Fail
Gobo Reset Fail
R-Gobo Reset Fail
Effect Reset Fail
R-Effect Reset Fail
Frost Reset Fail
Indicated moving part f ailed going to home
position after power up or fixtur e res et · Check part’s free mov ement and integrity
· Check sen sors’ wiring an d p osi ti on
· Check stepper motor, bel t, and driver board
· Check the correspondin g control board