Chip PC CDC01927 manual Non-standard LAN cabling, Flex-Jack terminal block contact #

Models: CDC01927

1 61
Download 61 pages 46.68 Kb
Page 28
Image 28
6.3Non-standard LAN cabling

Jack PC Hardware User Manual - Training Department

Version 0506

6.3Non-standard LAN cabling

In some cases cable could be a non standard cable or the far end (patch panel) connected in

anon-standard way (not in accordance to TIA-568-A or B). In such case you will have to do slightly more work mapping the existing non-standard connections.

Please refer to the table bellow. This table should be filled at the far end by looking at the actual connections. Fill out the second column and then use the third column to connect the wires to the Flex-Jack terminal block according to the numbering shown in the third colum.

RJ-45 Pin

Color (Fill actual color)

Flex-Jack terminal block contact #

TIA-568-A Color

TIA-568-B Color

1

 

3

White - Green

White - Orange

2

 

2

Green

Orange

3

 

4

White - Orange

White - Green

4

 

6

Blue

Blue

5

 

5

White - Blue

White - Blue

6

 

1

Orange

Green

7

 

7

White - Brown

White - Brown

8

 

8

Brown

Brown

Metal

 

Tab

Shield

Shield

Shield

 

 

 

 

 

Table 6.1 - Non-standard wiring table

 

See picture bellow of the Flex-Jack terminal block connections and numbering. Note that contact numbre 8 is at the left (closest to the A/B marking on the label).

Tab

Figure 6.1 - Flex-Jack terminal block numbering

For example, if you have a non-standard wire, and you wrote in the first line of the table above (RJ-45 Pin number 1) = green, then you need to connect the green wire (on the Jack PC side) to connector number 3 in the Flex-Jack terminal block.

28

Page 28
Image 28
Chip PC CDC01927 manual Non-standard LAN cabling, Flex-Jack terminal block contact #