Power*

Section 4: Maintenance

Figure 4.6. Inside the Lamp Compartment

Step 5 ' Close lamp door – Once the lamp is inserted, carefully close the spring-loaded lamp door and lock it by tightening the two lamp door screws.

Watch your fingers! The lamp door is spring- loaded and will snap close. Keep fingers clear from the lamp compartment opening when closing the lamp door.

Step 6 ' Turn the Projector on (if applicable) or Switch back to the original Lamp

Operation Mode – Press to turn the projector on. If you performed a hot- swap, use the Lamp menu to return to the original lamp operation mode you were in.

Step 7 ' Reset Lamp Hours – Access the Lamp menu (item 5. in Main Menu) and select the submenu for the lamp that you are replacing – More, Lamp 1 or More, Lamp 2. From the submenu, select the Change Lamp option. Enter the new serial number in the Lamp S/N text box. When the new number is recorded, the lamp timer will automatically reset to “0” hours and begin to log time.

NOTES: 1) Once entered, the new lamp serial number is also automatically added to the Lamp History submenu (read-only). 2) Lamp life data is required for warranty claims.

IMPORTANT

If you fail to enter a serial number the lamp timer will not automatically reset to “0” and inaccurate lamp hours will be shown in the Status menu. The lamp life limit may then expire prematurely.