12-14
Cisco TelePresence System 3200
OL-14521-01
Chapter 12 Field-Replaceable Unit Guide
Replacing a Light Fixture—Part Number CTS-LIGHT-FIXT
Step 8 Attach the privacy panels to the table sections.
Note If required, adjust the privacy panel sections so that ther e is an equal amount of space between
each section.
Step 9 If required, replace the cable cover for the right end privacy panel as shown in Figure 7-46 and add cable
ties to bundle the microphone cable with other cables.
Step 10 Test the microphone by performing the procedures in the “Setting Up the Microphones” section on
page 10-13.
Replacing a Light Fixture—Part Number CTS-LIGHT-FIXT
Required Information, Tools, and Equipment
To disassemble and reassemble portions of the Cisco TelePresence 3200, you need the following
information, tools, and equipment:
Cisco TelePresence System Release 1.4 Administrator’s Guide, OL-13676-03
Power screwdriver with 2.5, 3, and 6 mm (standard or round) Allen bits, or standard 2.5, 3, and 6 mm
Allen wrenches
Tip A round-head Allen bit allows the bit to work at an angle instead of only straight out, which is
helpful in tight spots.
Manual screwdrivers, Phillips and flat head types
Metric wrenches, 10 to 15 mm
Masking tape
Step stool or small step ladder
Laptop computer attached to network (for troubleshooting or reference)

Replacement Bulbs

A Field Replacement Unit consisting of three 5-foot and two 4-foot 4100 K bulbs is available from Cisco
Customer Service. The part number is CTS-3000-BULBS.
If one or more bulbs need replacement, it is recommended that all five bulbs are replaced for lighting
uniformity.
Note The light fixtures installed during assembly have a 4100 K rating. If you se t the Plasma display to
another value you need to purchase and replace the light fixtures to match the new color temperature
setting.