12-24
Cisco TelePresence System 3200
OL-14521-01
Chapter 12 Field-Replaceable Unit Guide
Replacing a Second Row Table Top Section
Replacing a Second Row Table Top Section
Complete these steps to replace a second row table top section.
Required Information, Tools, and Equipment
To remove and replace a second row table top, you need the following tools:
Medium and large Phillips screwdriver
10 mm wrench
Tip A 10 mm open end ratcheting wrench is useful to loosen and tighten the draw bol ts.
Furniture sliders (recommended but not required)
Note Furniture sliders are flat plastic pieces that you place under the table legs before you move the
table. Using furniture sliders can make moving the second row table easier.
Note Make sure to retain all screws, connectors, and other parts during the disassembly.

Removing and Replacing a Second Row Table Top Section

Step 1 Remove the privacy panel from the following table top sections:
The table top section to be replaced
All table sections to the right of the table top section to be replaced
Note See Chapter 7, “Building the Second Row Table Assembly” for expanded views of the privacy
panels.
Step 2 Remove the microphone from the table top section to be replaced. See Figure 7-38 for an expanded view
of the microphone and its attachment hardware.
Step 3 Disconnect the microphone from the audio/video expansion unit, route the cable through the t able top
section, and remove the microphone.
The microphone cable routes from the audio/video expansion un it to the table top section by way of the
cable gutters on the second row table. The gutters are behi nd the privacy panels that you removed in
Step 1.
Step 4 If required, remove the cable cover for the right end privacy panel as shown in Figure 7-46 and remove
cable ties that bundle the microphone cable with other cables.
Step 5 Remove the privacy panel alignment bracket.
See Chapter 7, “Building the Second Row Table Assembly” for the location of the privacy panel
alignment brackets.