Chapter 3 Installing the Wide Area Virtualization Engine

Installing the WAVE Appliance on a Tabletop

Installing the WAVE Appliance on a Tabletop

When you install a WAVE appliance on a workbench or tabletop, ensure that the surface is clean and in a safe location and that you have considered the following points:

The WAVE appliance should be installed off the floor. (Dust that accumulates on the floor is drawn into the interior of the chassis by the cooling fans. Excessive dust inside the WAVE appliance can cause overtemperature conditions and component failures.)

There must be approximately 19 inches (48.26 cm) of clearance at the front and rear of the WAVE appliance for accessing network cables or equipment.

The front should be completely clear. Leave 0.4 inches (10-mm) of clearance on the sides and top of the appliance and at least 2.0 inches (50 mm) of clearance in the rear. The rear vents should be completely clear.

To install the WAVE appliance on a workbench or tabletop, follow these steps:

Step 1 Remove any debris and dust from the tabletop or workbench, as well as from the surrounding area. Also make sure that your path between the WAVE appliance and its new location is unobstructed.

Step 2 Place the chassis on the tabletop or workbench.

Step 3 Ensure that no exhaust air from other equipment will be drawn into the chassis. Also make sure that there is adequate clearance at the front and rear of the chassis.

Installing the WAVE Appliance on a Wall

You can mount the WAVE appliance on a wall or underneath a desk or workbench using the optional mounting sleeve. See Figure 3-1 on page 3-3. Make sure that you consider the location requirements as described in the “Installing the WAVE Appliance on a Tabletop” section on page 3-2.

 

Cisco Wide Area Virtualization Engine 274 and 474 Hardware Installation Guide

3-2

OL-17739-01

Page 36
Image 36
Cisco Systems 474, 274 manual Installing the Wave Appliance on a Tabletop, Installing the Wave Appliance on a Wall