Chapter3 Installing the Content Engine
Installing a CE-511 or CE-566 Unit
3-6
Cisco Content Engine 511 and 566 Hardware Installation Guide
OL-5756-01
To install the CE-511 and CE-566 in the 4-post rack, follow these steps:
Step1 Select a 1-RU-size location in the rack. Starting with the right front side of the
rack (as viewed from the front of the Content Engine), install a clip nut or cage
nut in the top and bottom positions of the 1-RU location that you selected (see
Figure 3-4) and then install a clip nut or cage nut in the corresponding positions
on the rear of the rack. Repeat this step for the left front side of the rack and the
corresponding location on the rear of the rack.
Figure3-4 Installing Clip Nuts or Cage Nuts
Step2 Remove the inner slide rails from the slide rail assemblies by pressing the release
latches on the sides of the slide rail assemblies. (See Figure3-5.)
1Cage nuts 2Clip nuts