Chapter 3 Initial Configuration

Configuring CPU Switch Module Redundancy

Configuring Maintenance Mode

You can configure the Cisco ONS 15530 to enter the redundancy maintenance mode. Configuration synchronizations and standby CPU switch module fault reporting are suppressed in maintenance mode. Upon exiting maintenance mode and reverting to redundant mode, the standby switch CPU switch module reboots to the hot-standby state.

Note When the system is in maintenance mode, switchovers only occur by entering the redundancy switch-activity force command, or physically removing the active CPU switch module.

To configure maintenance mode, perform the following steps, beginning in global configuration mode:

 

Command

Purpose

Step 1

 

 

Switch(config)# redundancy

Enters redundancy configuration mode.

 

Switch(config-red)#

 

Step 2

 

 

Switch(config-red)# maintenance-mode

Configures the system in maintenance mode.

 

 

 

Example

The following example shows how to configure redundancy maintenance mode:

Switch(config)# redundancy

Switch(config-red)# maintenance-mode

This command will place the system in SIMPLEX mode [confirm] y

Displaying the CPU Switch Module Redundancy Configuration and Status

To display the CPU switch module redundancy configuration and status, use the following privileged EXEC commands:

Command

Purpose

 

 

show redundancy summary

Displays the redundancy configuration and status.

 

 

show redundancy capability

Displays capabilities of the active and standby CPU

 

switch modules and the software version that is

 

running.

 

 

show redundancy running-config-file

Displays the running configuration file on the standby

 

CPU switch module.

 

Note This command is only available on a terminal

 

connected to the standby CPU switch module.

 

 

 

Cisco ONS 15530 Configuration Guide and Command Reference

3-20

78-16019-02, Cisco IOS Release 12.2(18)SV2

Page 20
Image 20
Cisco Systems 78-16019-02 manual Configuring Maintenance Mode, Show redundancy summary, Show redundancy capability