Chapter 3 Initial Configuration
Configuring CPU Switch Module Redundancy
Configuring Maintenance Mode
You can configure the Cisco ONS 15530 to enter the redundancy maintenance mode. Configuration synchronizations and standby CPU switch module fault reporting are suppressed in maintenance mode. Upon exiting maintenance mode and reverting to redundant mode, the standby switch CPU switch module reboots to the
Note When the system is in maintenance mode, switchovers only occur by entering the redundancy
To configure maintenance mode, perform the following steps, beginning in global configuration mode:
| Command | Purpose |
Step 1 |
|
|
Switch(config)# redundancy | Enters redundancy configuration mode. | |
|
| |
Step 2 |
|
|
Configures the system in maintenance mode. | ||
|
|
|
Example
The following example shows how to configure redundancy maintenance mode:
Switch(config)# redundancy
This command will place the system in SIMPLEX mode [confirm] y
Displaying the CPU Switch Module Redundancy Configuration and Status
To display the CPU switch module redundancy configuration and status, use the following privileged EXEC commands:
Command | Purpose |
|
|
show redundancy summary | Displays the redundancy configuration and status. |
|
|
show redundancy capability | Displays capabilities of the active and standby CPU |
| switch modules and the software version that is |
| running. |
|
|
show redundancy | Displays the running configuration file on the standby |
| CPU switch module. |
| Note This command is only available on a terminal |
| connected to the standby CPU switch module. |
|
|
| Cisco ONS 15530 Configuration Guide and Command Reference |