Cisco MDS 9124e Fabric Switch for HP c-Class BladeSystem 55
Environmental requirements
To ensure proper operation, the switch must not be subjected to environmental conditions beyond
those for which it was tested. The ranges specified in Table 16 list the acceptable environment for
both operating and non-operating conditions.
Table 15 Environmental requirements
Supported SFPs
Do not use unsupported SFPs; they can affect switch operability. They may not fit correctlyand may
void your warranty. See Optional hardware kits for a list of supported SFPs.
For a complete list of supported devices, refer to the latest version of the HP StorageWorks SAN
design refe rence guide:
http://h18000.www1.hp.com/products/storageworks/san/documentation.html
Supported HBAs
For a list of HBAs that have been tested and are known to work with the SAN switches, refer to the
latest version of the HP StorageWorks SAN design reference guide:
http://h18000.www1.hp.com/products/storageworks/san/documentation.htm
Condition Acceptable range during operation Acceptable range during non-operation
Ambient temperature 104°F/40 °C at sea level, derated
1 C per 1000 ft above sea level
-40°C to 70°C with maximum rate
of change of 20 C /hr
Humidity 5% to 90% relative humidity,
non-condensing
50% to 80% relative humidity,
non-condensing
Altitude 0 to 10,000 ft (3 km) above sea
level
0 to 40,000 ft (12 km) above sea
level
Shock 40 G, 2mS duration 140 G, 2mS duration
Vibration 0.5 G, 10 to 500 Hz 2.0 G, 5 to 500 Hz
Airflow 47 cubic ft per minute None required