Cisco Systems AIRCAP3602IAK9 manual Equipment Racks

Models: AIRCAP3602IAK9

1 146
Download 146 pages 14.51 Kb
Page 41
Image 41

Chapter 2 Preparing to Install the Router

General Site Requirements

Equipment Racks

You can mount the Cisco 3620 and Cisco 3640 routers in a 19-inch rack (with a 17.5- or 17.75-inch opening), a 23-inch rack, or a 24-inch rack.

The Cisco 3631 and Cisco 3660 routers can be mounted in a 19-inch rack (with a 17.5- or 17.75-inch opening), or a 23-inch rack.

The following information will help you plan your equipment rack configuration:

Allow clearance around the rack for maintenance.

Enclosed racks must have adequate ventilation. Ensure that the rack is not congested, because each router generates heat. An enclosed rack should have louvered sides and a fan to provide cooling air. Heat generated by equipment near the bottom of the rack can be drawn upward into the intake ports of the equipment above.

When mounting a chassis in an open rack, ensure that the rack frame does not block the intake ports or exhaust ports. If the chassis is installed on slides, check the position of the chassis when it is seated into the rack.

Baffles can help to isolate exhaust air from intake air, which also helps to draw cooling air through the chassis. The best placement of the baffles depends on the airflow patterns in the rack, which can be found by experimenting with different configurations.

When equipment installed in a rack (particularly in an enclosed rack) fails, try operating the equipment by itself, if possible. Power off other equipment in the rack (and in adjacent racks) to allow the router under test a maximum of cooling air and clean power.

Cisco 3600 Series Routers Hardware Installation Guide

 

OL-2056-05

2-5

 

 

 

Page 41
Image 41
Cisco Systems AIRCAP3602IAK9 manual Equipment Racks