2-89
Cisco ONS 15327 Troubleshooting Guide, R3.4
March 2004
Chapter2 Alarm Troublesho oting Alarm Procedures
2.6.121 MANSWTOINT
Not Alarmed (NA), Non-Service Affecting (NSA)
The Manual Switch To Internal Clock (MANSWTOINT) condition occurs when the NE timing source
is manually switched to the internal timing source.
Note MANSWTOINT is an informational condition. It does not require troubleshooting.
2.6.122 MANSWTOPRI
Not Alarmed (NA), Non-Service Affecting (NSA)
The Manual Switch To Primary Reference (MANSWTOPRI) condition occurs when the NE timing
source is manually switched to the primary timing source.
Note MANSWTOPRI is an informational condition. It does not require troubleshooting.
2.6.123 MANSWTOSEC
Not Alarmed (NA), Non-Service Affecting (NSA)
The Manual Switch To Second Reference (MANSWTOSEC) condition occurs when the NE timing
source is manually switched to the second timing source.
Note MANSWTOSEC is an informational condition. It does not require troubleshooting.
2.6.124 MANSWTOTHIRD
Not Alarmed (NA), Non-Service Affecting (NSA)
The Manual Switch To Third Reference (MANSWTOTHIRD) condition occurs when the NE timing
source is manually switched to the tertiary timing source.
Note MANSWTOTHIRD is an informational condition. It does not require troubleshooting.
2.6.125 MANUAL-REQ-RING
Not Alarmed (NA), Non-Service Affecting (NSA)
The Manual Switch Request on Ring (MANUAL-REQ-RING) condition occurs when a user in itiat es a
MANUAL RING command on two-fiber BLSR rings to switch from working to protect o r pro tec t t o
working.