Chapter 2 Alarm Troubleshooting

Alarm Procedures

Procedure: Clear the BKUPMEMP Alarm

Step 1 Verify that both XTC cards are powered and enabled by confirming lighted ACT/STBY LEDs on the XTC cards.

Step 2 If both XTC cards are powered and enabled, reset the active XTC card to it standby and make the standby XTC card active. Complete the “Reset the Active XTC Card in CTC” procedure on page 2-129.

Verify that the active card you reset is now standby. The ACT/STBY LED of this card should be amber, and the newly active XTC card LED should be green.

Step 3 If the XTC you reset does not reboot successfully, or the alarm has not cleared, call TAC (1-800-553-2447). If the TAC technician tells you to reseat the card, complete the “Remove and Reinsert (Reseat) the Standby XTC” procedure on page 3-3. If the TAC technician tells you to remove the card and reinstall a new one, follow the “Physically Replace a Card” procedure on page 2-130.

Note When replacing a card with an identical type of card, no additional CTC provisioning is required.

2.6.30BLSROSYNC

Major (MJ), Service Affecting (SA)

The BLSR Out Of Synchronization (BLSROSYNC) alarm is caused when you attempt to add or delete a circuit and a node on a working ring loses its DCC connection because all transmit and receive fiber has been removed. CTC cannot generate the ring table and causes the BLSROSYNC alarm.

Warning Invisible laser radiation might be emitted from the end of the unterminated fiber cable or connector. Do not stare into the beam directly with optical instruments. Viewing the laser output with certain optical instruments (for example, eye loupes, magnifiers, and microscopes) within a distance of 100

mmmight pose an eye hazard. Use of controls or adjustments or performance of procedures other than those specified might result in hazardous radiation exposure.

Procedure: Clear the BLSROSYNC Alarm

Step 1 Reestablish cabling continuity to the node reporting the alarm.

When the DCC is established between the node and the rest of the BLSR, it becomes visible to the BLSR and should be able to function on the circuits.

Step 2 If alarms occur when you have provisioned the DCCs, see the “EOC” section on page 2-48.

Step 3 If the alarm does not clear, log onto http://www.cisco.com/tac for more information or call TAC to report a service-affecting problem (1-800-553-2447).

Cisco ONS 15327 Troubleshooting Guide, R3.4

2-30

March 2004

 

 

Page 136
Image 136
Cisco Systems ONS 15327 manual Procedure Clear the Bkupmemp Alarm, Procedure Clear the Blsrosync Alarm

ONS 15327 specifications

Cisco Systems ONS 15327 is a high-performance optical networking solution tailored for service providers and enterprises looking to enhance their optical communication infrastructure. This versatile platform is recognized for its robust performance, scalability, and flexibility, making it suitable for a wide array of applications ranging from broadband access to metropolitan area networking.

One of the standout features of the ONS 15327 is its ability to handle multiple data types over a single platform. It supports a rich array of protocols, including Ethernet and SONET/SDH, allowing service providers to deliver a diverse portfolio of services to their customers. This multiservice capability simplifies the network architecture, reducing operational complexity and costs.

The ONS 15327 is designed with a modular architecture, which enables operators to customize and scale their network as demand grows. It supports a variety of card options for different media types, wavelengths, and capacity requirements. This modularity not only facilitates straightforward upgrades but also allows for efficient network management.

In terms of technology, the ONS 15327 leverages dense wavelength division multiplexing (DWDM) capabilities to maximize the utilization of available fiber bandwidth. This allows for an impressive increase in transmission capacity without the need for additional fiber installations, making it a cost-effective solution for expanding networks.

Another significant characteristic of the Cisco ONS 15327 is its advanced performance monitoring and management features. Built-in diagnostic tools provide real-time visibility into network performance, enabling prompt identification and troubleshooting of potential issues. This proactive approach to network management enhances service reliability and customer satisfaction.

Security is also paramount in the ONS 15327. The platform integrates various security features and protocols to protect the data traversing the network, ensuring compliance with industry standards and safeguarding sensitive information.

Furthermore, the equipment is designed for easy integration into existing infrastructures. Its compatibility with Cisco’s broader networking solutions allows for seamless interconnection with routers, switches, and other devices, facilitating comprehensive network solutions.

In conclusion, Cisco Systems ONS 15327 stands out as a powerful optical networking platform that combines versatility, scalability, and advanced management features. Its ability to support various protocols and harness optical technologies makes it an essential tool for organizations aiming to optimize their telecommunications infrastructure while minimizing costs and complexity.