Chapter 2 Alarm Troubleshooting

Alarm Procedures

Step 7 If all ONS nodes in the ring appear in the CTC network view, verify or not whether there are incomplete circuits:

a.Click the Circuits tab.

b.Verify that INCOMPLETE is not listed in the State column of any circuits.

Step 8 If you find circuits listed as incomplete, use an optical test set to verify that these circuits are not working circuits that continue to pass traffic.

For specific procedures to use the test set equipment, consult the manufacturer.

Step 9 If the incomplete circuits are not needed or are not passing traffic, delete the incomplete circuits.

Complete the “Delete a Circuit” procedure on page 2-128.

Step 10 Recreate the circuit with the correct circuit size. Refer to the Cisco ONS 15327 Procedure Guide. Step 11 Log back in and verify that all circuits terminating in the reporting card are active:

a.Click the Circuits tab.

b.Verify that the State column lists all circuits as active.

Step 12 If the alarm does not clear, clean the far-end optical fiber according to site practice. If no site practice exists, complete the procedure in the Cisco ONS 15327 Procedure Guide.

Step 13 If the alarm does not clear, complete the “Physically Replace a Card” procedure on page 2-130for the OC-N/DS-N cards.

Note When replacing a card with an identical type of card, no additional CTC provisioning is required.

Step 14 If the alarm does not clear, log onto http://www.cisco.com/tac for more information or call TAC to report a service-affecting problem (1-800-553-2447).

2.6.187 UNEQ-V

Major (MJ), Service Affecting (SA)

An SLMF UNEQ VT alarm indicates that the node is receiving SONET path overhead with bits 5, 6, and 7 of the V5 overhead byte all set to zeroes. The source of the problem is the node that is transmitting the VT-level signal into the node reporting the UNEQ-P. The problem node is the next node upstream that processes the signal at the VT level. The V in UNEQ-V indicates that the failure has occurred at the VT layer.

Warning Invisible laser radiation might be emitted from the end of the unterminated fiber cable or connector. Do not stare into the beam directly with optical instruments. Viewing the laser output with certain optical instruments (for example, eye loupes, magnifiers, and microscopes) within a distance of 100

mmmight pose an eye hazard. Use of controls or adjustments or performance of procedures other than those specified might result in hazardous radiation exposure.

Caution Always use the supplied electrostatic discharge wristband when working with a powered ONS 15327. Plug the wristband cable into the ESD jack located between the top high-speed and XTC slots.

 

 

Cisco ONS 15327 Troubleshooting Guide, R3.4

 

 

 

 

 

 

March 2004

 

 

2-123

 

 

 

 

 

Page 229
Image 229
Cisco Systems ONS 15327 manual Uneq-V, 123

ONS 15327 specifications

Cisco Systems ONS 15327 is a high-performance optical networking solution tailored for service providers and enterprises looking to enhance their optical communication infrastructure. This versatile platform is recognized for its robust performance, scalability, and flexibility, making it suitable for a wide array of applications ranging from broadband access to metropolitan area networking.

One of the standout features of the ONS 15327 is its ability to handle multiple data types over a single platform. It supports a rich array of protocols, including Ethernet and SONET/SDH, allowing service providers to deliver a diverse portfolio of services to their customers. This multiservice capability simplifies the network architecture, reducing operational complexity and costs.

The ONS 15327 is designed with a modular architecture, which enables operators to customize and scale their network as demand grows. It supports a variety of card options for different media types, wavelengths, and capacity requirements. This modularity not only facilitates straightforward upgrades but also allows for efficient network management.

In terms of technology, the ONS 15327 leverages dense wavelength division multiplexing (DWDM) capabilities to maximize the utilization of available fiber bandwidth. This allows for an impressive increase in transmission capacity without the need for additional fiber installations, making it a cost-effective solution for expanding networks.

Another significant characteristic of the Cisco ONS 15327 is its advanced performance monitoring and management features. Built-in diagnostic tools provide real-time visibility into network performance, enabling prompt identification and troubleshooting of potential issues. This proactive approach to network management enhances service reliability and customer satisfaction.

Security is also paramount in the ONS 15327. The platform integrates various security features and protocols to protect the data traversing the network, ensuring compliance with industry standards and safeguarding sensitive information.

Furthermore, the equipment is designed for easy integration into existing infrastructures. Its compatibility with Cisco’s broader networking solutions allows for seamless interconnection with routers, switches, and other devices, facilitating comprehensive network solutions.

In conclusion, Cisco Systems ONS 15327 stands out as a powerful optical networking platform that combines versatility, scalability, and advanced management features. Its ability to support various protocols and harness optical technologies makes it an essential tool for organizations aiming to optimize their telecommunications infrastructure while minimizing costs and complexity.