Temperature and Humidity Requirements
Table 1 and Table 2 list the nominal operating and
Table 1 | Operating Environment |
|
|
|
|
| |
Specification | Minimum | Maximum | |
|
|
| |
Temperature, ambient operating | 32°F (0°C) | 104°F (40°C) | |
|
|
| |
Humidity, ambient | 10% | 90% | |
|
|
| |
Altitude, operating and | 13,123 ft (4000 m) | ||
|
|
| |
Vibration, operating | — | 5 to 200 Hz, 0.5 g (1 octet/min.) | |
|
|
|
|
Table 2 |
|
| |
|
|
| |
Specification | Minimum | Maximum | |
|
|
| |
Temperature, ambient | 149°F (65°C) | ||
|
|
| |
Humidity, ambient | 5% | 95% | |
|
|
| |
Altitude, operating and | 13,123 ft (4000 m) | ||
|
|
| |
Vibration, | — | 5 to 200 Hz, 1 g (1 octet/min.) | |
|
|
| 200 to 500 Hz, 2 g (1 octet/min.) |
|
|
|
|
Verifying Contents After Unpacking
Power cables, manuals, and other additional items are packaged in separate boxes. After you have unpacked the system, verify that you have received all the required components and documentation.
Step 1 Using the packing list as a guide, verify that you have received everything that is listed, including the following:
a.System hardware documentation and software documentation (if ordered).
b.Optional equipment that you ordered, such as transceivers (GBICs), flash cards, cables, or special connectors.
Step 2 Check that all equipment you ordered is installed in the chassis.
Step 3 Ensure that the system configuration matches the packing list.