5

Temperature and Humidity Requirements

Table 1 and Table 2 list the nominal operating and non-operating environment requirements. Any measurements that approach
the minimum or maximum of a range indicate a potential problem.
Table1 Operating Environment
Table2 Non-operating Environment
Verifying Contents After Unpacking
Power cables, manuals, and other additional items are packaged in separate boxes. After you have unpacked the system, verify
that you have received all the required components and documentation.
Step1 Using the packing list as a guide, verify that you have received everything that is listed, including the following:
a. System hardware documentation and software documentation (if ordered).
b. Optional equipment that you ordered, such as transceivers (GBICs), flash cards, cables, or special connectors.
Step2 Check that all equipment you ordered is installed in the chassis.
Step3 Ensure that the system configuration matches the packing list.

Specification Minimum Maximum

Temperature, ambient operating 32°F (0°C) 104°F (40°C)
Humidity, ambient (non-condensing) operating 10% 90%
Altitude, operating and non-operating –197 ft (–60 m) 13,123 ft (4000 m)
Vibration, operating 5 to 200 Hz, 0.5 g (1 octet/min.)

Specification Minimum Maximum

Temperature, ambient non-operating and storage –4°F (–20°C) 149°F (65°C)
Humidity, ambient (non-condensing) non-operating and storage 5% 95%
Altitude, operating and non-operating –197 ft (–60 m) 13,123 ft (4000 m)
Vibration, non-operating 5 to 200 Hz, 1 g (1 octet/min.)
200 to 500 Hz, 2 g (1 octet/min.)