Environmental Specifications

Table A-2lists the environmental specifications for the server.

Table A-2

Environmental Specifications

 

 

 

 

Description

 

Specification

 

 

Temperature, operating:

50 to 95°F (10 to 35°C)

Derate 1°C for every 1000 ft (304 m) up to a

 

maximum altitude of 10,000 ft (3048 m).

 

 

 

Temperature, nonoperating

–40 to 149°F (–40 to 65°C)

within altitude: 0 to 40,000 feet (0 to 12,000

 

meters)

 

 

 

 

Humidity (RH), noncondensing

5 to 93%

 

 

 

Altitude

 

0 to 10000 feet

 

 

Sound power level

65.5 dBA

Measure A-weighted per ISO7779 LwAd (dBA)

 

Operation at 73°F (23°C)

 

 

 

Sound power level

6.8 Bels

Measure A-weighted per ISO7779 LwAd (Bels)

 

Operation at 73°F (23°C)

 

 

 

 

Power Specifications

Table A-3lists the specifications for each power supply (Cisco part number R2X0-PSU2-650W).

Table A-3 Power Supply Specifications

Description

Specification

 

 

AC-input voltage

115 to 230 VAC nominal

 

(Range: 90 to 264 VAC)

 

 

AC-input frequency

50 to 60 Hz nominal

 

(Range: 47 to 63 Hz)

 

 

Maximum AC-input current

10 Amps

 

 

Maximum output power for each power

650 W (up to two power supplies can be installed)

supply

 

 

 

Power supply output voltage

Main power: 12 VDC

 

Standby power: 5 VDC

 

 

You can get more specific power information for your exact server configuration by using the Cisco UCS Power Calculator:

http://www.cisco.com/assets/cdc_content_elements/flash/dataCenter/cisco_ucs_power_calculator/

Cisco UCS C210 Server Installation and Service Guide

 