Step 2 Install a TPM:

a.Align the connector that is on the underside of the new TPM with motherboard socket JP2, and then press firmly on both ends of the TPM to press the connector into the socket.

b.Replace the securing screw that holds the TPM to the motherboard standoff.

c.Replace the PCIe riser card assembly.

See the “Replacing a PCIe Riser Card Assembly” section on page 3-32for instructions.

d.Replace the top cover.

e.Replace the server in the rack, replace power cords and any other cables, and then power on the server by pressing the Power button.

Note The TPM must be enabled in the server BIOS before you can use it. If you have not previously enabled the TPM, continue with the next step.

Figure 3-16 Removing and Replacing a TPM

1 3

2

1

3

TPM

2 Motherboard socket JP2

Securing screw

Step 3 Activate the TPM in the server BIOS:

a.Either attach a VGA monitor and USB keyboard to the server, or log in remotely to the CIMC interface of the server and open a virtual KVM console window. For instructions on using the CIMC, refer to the Cisco UCS C-SeriesRack-Mount Server Configuration Guide.

b.Reboot the server.

Note You can reboot the server by pressing the Power button on the server; by selecting

Macros > Ctrl-Alt-Del on the Cisco KVM Console window menu bar; or by selecting Power Cycle Server on the Server Summary tab of the CIMC GUI.

c.Watch during bootup for the F2 prompt, and then press F2 to enter BIOS setup.

d.If you have already configured a BIOS Administrator password, enter it and skip to Step h.

e.If you have not set a BIOS Administrator password for the server, continue with this step.

 

 

Cisco UCS C210 Server Installation and Service Guide

 

 

 

 

 

 

OL-20887-02

 

 

3-31

 

 

 

 

 

Page 69
Image 69
Cisco Systems UCS C210 manual Tpm