Appendix

Table C-1

Cisco UCS C210 RAID Controller Options

 

 

 

 

 

 

Max.

 

 

 

 

 

 

 

 

Internal

 

 

Opt.

 

 

Controller

 

Style

Drives

SAS

SATA

BBU

RAID Levels

Required Cables

 

 

 

 

 

 

 

 

 

Intel ICH10R1

 

Integrated

4

No

Yes

No

0, 1

1 SATA2

 

 

 

 

 

 

 

 

(R210-SATACBL)

 

 

 

 

 

 

 

 

 

LSI 1064E

 

Mezzanine

4

Yes3

Yes

No

0, 1, 1E

Extender:

 

 

 

 

 

 

 

 

1 Long SAS

 

 

 

 

 

 

 

 

(R210-SASCBL)

 

 

 

 

 

 

 

 

Expander:

 

 

 

 

 

 

 

 

1 Short SAS

 

 

 

 

 

 

 

 

(SASCBLSHORT)

 

 

 

 

 

 

 

 

 

LSI MegaRAID

 

PCIe

4

Yes4

Yes

Yes

0, 1, 5, 6, 10,

Extender:

9280-4i4e

 

 

 

 

 

 

50, 60

1 long SAS

 

 

 

 

 

 

 

 

(R210-SASCBL)

 

 

 

 

 

 

 

 

Expander:

 

 

 

 

 

 

 

 

1 Short SAS

 

 

 

 

 

 

 

 

(SASCBLSHORT)

 

 

 

 

 

 

 

 

 

LSI MegaRAID

 

PCIe

16

Yes

Yes

Yes

0, 1, 5, 6, 10,

Extender:

9261-8i

 

 

 

 

 

 

50, 60

2 Long SAS

 

 

 

 

 

 

 

 

(R210-SASCBL)

 

 

 

 

 

 

 

 

Expander:

 

 

 

 

 

 

 

 

2 Short SAS

 

 

 

 

 

 

 

 

(SASCBLSHORT)

 

 

 

 

 

 

 

 

 

1.The integrated ICH10R controller must be enabled in the BIOS. This controller is not compatible for use with VMWare ESX/ESXi Server software in any generation or version of the Cisco UCS C210 server.

2.The integrated ICH10R controller cannot be used with the optional expander.

3.You cannot mix SAS and SATA drives when using a 1064E-based controller.

4.You can mix SAS and SATA drives when using an LSI MegaRAID card. However, you cannot mix SAS and SATA drives within a volume.

Enabling the Integrated Intel ICH10R RAID Controller in the BIOS

Note The integrated ICH10R RAID controller is not compatible for use with VMWare ESX/ESXi Server software in any generation or version of the Cisco UCS C200 server.

When using the integrated RAID, you must enable the ICH10R controller in SW RAID mode.

Step 1 Boot the server and press F2 when prompted to enter the BIOS Setup utility.

Step 2 Select the Advanced tab, then Mass Storage Controllers Configuration.

Step 3 Set Onboard SATA Controller to Enabled. Set SATA Mode to SW RAID.

Step 4 Press F10 to save your changes and exit the utility.

Cisco UCS C210 Server Installation and Service Guide

 

C-2

OL-20887-02

 

 

 

Page 96
Image 96