GS ^ n1 n2 n3

[Function]

Executing the macro

[Code]

<1D>H<5E>H<n1><n2><n3>

[Range]

0

n1

255

 

0

n2

255

 

0

n3

1

[Outline]

Executing contents defined in macro.

 

n1 : The number of times of macro execution

 

n2 : Waiting time on macro execution

 

Waiting time of n2 × 100 msec is given for every execution.

 

n3 : Macro execution mode

 

n3=0 Continuous execution:

 

The Macro is executed “n1” times continuously at the

 

time interval specified by “n2”.

 

n3=1 Execution by FEED Switch:

 

After waiting for the time specified by “n2”, the

 

ARARM LED flickers and the FEED switch is waiting to

 

be pressed. When it is pressed, the macro is executed

 

once. This action is repeated “n1” times.

[Caution]

• When this command is received while in macro definition,

 

suspension of macro definition is indicated. At this time, the

 

defined content is cleared.

 

• No execution takes place when the macro is held undefined

 

or n1=0.

 

• While in macro execution with n3=1, paper feed with the FEED

 

switch is not available.

[Default]

The initial value is not defined.

[See Also]

GS :

[Sample Program]

Refer to Sample Program and Print Results for GS: on page

 

101.

— 113 —

Page 131
Image 131
Citizen CBM1000 manual GS n1 n2 n3, See Also Sample Program