4.7 Grounding Equipment and Methods

Removal and Replacement Preliminaries

4.7 Grounding Equipment and Methods

Grounding equipment must include either a wrist strap or a foot strap at a grounded workstation.

When seated, wear a wrist strap connected to a grounded system. Wrist straps are flexible straps with a minimum of one megohm ±10% resistance in the ground cords. To provide proper ground, wear a strap snug against the skin at all times. On grounded mats with banana-plug connectors, connect a wrist strap with alligator clips.

When standing, use foot straps and a grounded floor mat. Foot straps (heel, toe, or boot straps) can be used at standing workstations and are compatible with most types of shoes or boots. On conductive floors or dissipative floor mats, use them on both feet with a minimum of one-megohm resistance between the operator and ground. To be effective, the conductive strips must be worn in contact with the skin.

Other grounding equipment recommended for use in preventing electrostatic damage includes:

Antistatic tape

Antistatic smocks, aprons, or sleeve protectors

Conductive bins and other assembly or soldering aids

Non-conductive foam

Conductive tabletop workstations with ground cord of one-megohm resistance

Static-dissipative table or floor mats with hard tie to ground

Field service kits

Static awareness labels

Material-handling packages

4–6

Maintenance and Service Guide

Page 67
Image 67