Technical Product Manual - DCT1900

Maintenance, Fault Signalling

CHAPTER 3

Fault Signalling

3.1Introduction

This chapter describes how maintenance personnel or system managers are informed about faults in the DCT1900 system. Faults are signalled to the outside world in the following ways:

General Alarm/Service Message System Screen of CSMW software Individual user complaints Common user complaints Alarms to MS (Mobility only)

Furthermore, LEDs and the service display of the Portable Telephone are discussed. Although they cannot be taken as fault signaling devices, they can help diagnose faults.

3.2General Alarm/Service Message

When the CPU has classified a fault as "service" (persistent faults), a general alarm is raised, see Chapter 2, Paragraph 2.2. Upon a general alarm, a general alarm signal is activated and a "fault" report is written in the service table, which can be read by the CSMW software. The fault report indicates the type of fault, type of board, location and time and date. The format of a fault report and a list of fault codes can be found in Chapter 4.

The local system manager or maintenance engineer is informed about a general alarm in three ways:

General alarm signal

"System Service Required" message on the PC–screen when the CSMW software is running Alarm message to the MS

LED 5 on the CPU will also be turned on in the case of a general alarm. However, it may also be on as a result of an "info" or "fault" error table entry.

General Alarm Signal

The general alarm signal from a CPU is routed via the general alarm cable to the MCCB where it activates a general alarm relay. Via this make/break relay contact, a lamp or a buzzer or any other type of alarm device can be activated. The alarm signalling can be cleared by selecting from the CSMW menu bar System-Reset-Alarm Relay.

"System Service Required"

When the PC is running the CSMW software, a pop–up window containing the message "System Service Required" appears on the PC screen as soon as the general alarm is activated. If CSMW software is started after the occurrence of a general alarm, the "System Service Required" message will not appear on the screen. The general alarm signal is the only warning.

Alarm Message

When a fault is classified as "service" and posted in the service table, an alarm message is sent to the MS which enables remote monitoring of the operational state of a DCT1900 system. This capability is only applicable in the Mobility configuration.

Maint-DCT1900/R8/mw

3-1

© 2000-2005

 

Page 361
Image 361
Nortel Networks DCT1900 Fault Signalling, General Alarm/Service Message, General Alarm Signal, System Service Required