Technical Product Manual - DCT1900

Product Specifications, System Boards

6.6Speech Link Unit, SLU - REX-BRD0015 or ROFNB 157 16/1

Environmental

 

Temperature

 

Operating

: 32 to 104°F (0 to 70°C)

Storage

: -40 to 158°F (-40 to 70°C)

Relative humidity

: 20 to 80%, non condensing

General Specifications

 

Length x width

13.5" x 7.7" (343 x 195.6mm)

Current Limitation

 

Current limitation of the Base

 

Stations power

: 1.3 A (T = 25 °C)

 

0.75 A (T = 70 °C)

Transport Data Rate

 

Data rate between SLU and

 

Base Station

: 384 kbit/s

Speech Coding

 

Telephone exchange side

: 64 kbit/s PCM (A–law or μ–law, country dependent,

 

downloaded from CPU)

Base Stations side

: 32 kbit/s ADPCM

DTMF Levels

Country dependent (downloaded from CPU)

Artificial Leakage

 

 

Only if a DTU is used

: -24 dB

Dial Tone Detection

 

 

Sensitivity level

: -29 dBm

Detection time

:

800 ms

Frequencies

:

350/440 Hz

6-4

Specs-DCT1900/R8/mw

 

© 2000-2005

Page 184
Image 184
Nortel Networks DCT1900 manual Speech Link Unit, SLU REX-BRD0015 or Rofnb 157 16/1