Technical Product Manual - DCT1900

Configuration Directions, Base Station Powering

The following resistance values for the twisted pairs are used:

z 26 AWG wire cable

:

.082

/ft.

z

24 AWG wire cable

:

.055

/ft.

z

22 AWG wire cable

:

.034

/ft.

Tables

 

Cable

 

 

Maximum cable length

 

Type

Wire size ()

Capacitance

Superimposed noise

Superimposed noise

 

AWG

 

8 mV/pHz

10 mV/pHz

 

 

 

CLU

SLU

CLU

SLU

 

 

 

11/2

CLU-s

11/2

CLU-s

Twisted pair

26ga

15 pF/ft.

7540 ft.

4920 ft.

6560 ft.

4260 ft.

 

 

 

 

 

 

 

Twisted pair

24ga

15 pF/ft.

11480 ft.

6880 ft.

9840 ft.

6230 ft.

Twisted pair

22ga

40 pF/ft.

6880 ft.

4260 ft.

5900 ft.

3930 ft.

Double twisted pair

22ga

40 pF/ft.

6160 ft.

3930 ft.

4920 ft.

3280 ft.

(J–Y (St)Y 2 2 0.6)

 

 

 

 

 

 

Table 4–1 "Data Limited" Cable Length

Worst Case Power Consumption of Base Station =

7.5

W

Based pm Class 3

=

23

dbm

Minimum Input Voltage of Base Station

=

21

V

 

 

 

Maximum Cable Length (feet)

 

 

Wire size

Power Supply Voltage

Power Supply Voltage

Power Supply Voltage

()

 

27.5 V

 

42 V

 

48 V

 

0 EPP

 

1 EPP

0 EPP

 

1 EPP

0 EPP

 

1 EPP

26 awg

418

 

627

1405

 

2107

1842

 

2763

24 awg

627

 

941

2107

 

3161

2763

 

4145*

22 awg

1026

 

1539

3448*

 

5172*

4522*

 

6782*

* Cable lengths should never exceed the values given in Table 4–1, because of data limitations

Table 4–2 Maximum Cable Length when Powering via Data Pairs and Express Powering Pairs

Config-DCT1900/R8/mw

4-5

© 2000-2005

 

Page 125
Image 125
Nortel Networks DCT1900 manual Tables, Clu Slu