Nortel Networks DCT1900 manual Relative Counters, Counters for CPU, Counters for Board Controllers

Models: DCT1900

1 400
Download 400 pages 50.54 Kb
Page 359
Image 359

Technical Product Manual - DCT1900

Maintenance, Test and Maintenance Software

Relative Counters

A relative counter counts all resets since the power–on. The counter is cleared each time the power is cycled or at a CPU reset (button or watch–dog). Relative counters have a threshold level. When the threshold level is exceeded, a general alarm with fault code 3 is generated. Relative counter values are halved every 24 hours.

Counters for CPU

The CPU board has the following counters for CPU circuits:

Absolute Counters:

 

Power On reset

: increments at every power on.

Watch–dog reset

: increments at every unexpected CPU watch–dog reset.

Relative Counters:

 

HSCX reset

: increments at every HSCX reset.

HDLC A reset

: increments at every HDLC A reset.

HDLC B reset

: increments at every HDLC B reset.

8031 (BC) reset

: increments at every 8031 reset.

Note:

HSCX = High Level Serial Controller Extended

HDLC = High Level Digital Link Control

Counters for Board Controllers

The CPU has the following counters for Board Controllers:

Absolute Counter

: increments on all type of resets, see Table 2–1.

Relative Counter

: increments at error (T&M reset/BC), increments at board insertion

 

(backplane reset).

Counters for Peripherals

The CPU has the following counters for peripherals:

Relative Counter

: increments at error (T&M reset/P).

Maint-DCT1900/R8/mw

2-9

© 2000-2005

 

Page 359
Image 359
Nortel Networks DCT1900 Relative Counters, Counters for CPU, Counters for Board Controllers, Counters for Peripherals