Nortel Networks DCT1900 manual TimeSlots, SysOrder, SysList

Models: DCT1900

1 400
Download 400 pages 50.54 Kb
Page 371
Image 371

Technical Product Manual - DCT1900

Maintenance, Fault Signalling

This option enables the display of information for a selected channel. Data is updated at every 8 frames. UP will increment DCA_carrier by one and scroll back to FIRST_CARRIER if beyond limits, DOWN will increment DCA_timeslot by one and scroll back to FIRST_SLOT if beyond limits.

TimeSlots

0123456790AB

-----BXB---

0-B

:

Free time slot

B

:

Blind time slot

X

:

Time slot in active use

This shows status of all 12 time slots on the carrier of the master bearer.

SysOrder

NnnnSsNnnnSs

01F4A5xxxx--

Nnnn

:

System number

Ss

:

RSSI value

Scroll through current list of systems and display the system number and RSSI of its best RFP’s best channel. Two systems are displayed at a time. UP/DOWN can be used to scroll through the list.

SysList

E Nnnn ASs F 1 01F4 AA2 3

E

: Index to current system in the list

Nnnn

: System number

A

: System allowed

Ss

: RSSI value

F

: Number of RFPs

Display information about a chosen system on the list of systems or the best one (FIRST ENTRY), if the selected one is not found. Users can use UP/DOWN to scroll through the list of systems.

Maint-DCT1900/R8/mw

3-11

© 2000-2005

 

Page 371
Image 371
Nortel Networks DCT1900 manual TimeSlots, SysOrder, SysList