Technical Product Manual - DCT1900

Product Specifications, System Boards

6.2Digital Trunk Unit, DTU-T1, CAS - REX-BRD0021 or 2/ROFNB 157 13/2

Compliance to Regulations and Standards

The DTU–T1 provides 2 standard T1 interfaces. The DTU–T1 complies with the following EIA/TIA recommendation:

EIA/TIA 464

: Private Branch Exchange (PBX) Switching Equipment for

Environmental

 

Voice–band Applications.

 

 

Temperature

 

 

Operating

: 32 to 104°F (0 to 70°C)

Storage

: -40 to 158°F (-40 to 70°C)

Relative humidity

: 20 to 80%, non condensing

General Specifications

 

 

Length x width

 

13.5" x 7.7" (343 x 195.6mm)

Digital Trunk Specification

 

 

Number of T1

 

 

interfaces per DTU

:

2

Bit rate

:

1.544 Mbit/s

Signalling

: Channel Associated Signalling with bit Robbing (CAS BR)

according to EIA/TIA 464–A FXS DSX–1, using firmware set RYS 105 660

6.3Digital Trunk Unit -DTU–T1,CCS - REX-BRD0021 or 2/ROFNB 157 13/3

The DTU–T1 provides 2 standard T1 interfaces. The DTU–T1 complies with the following EIA/TIA recommendation:

EIA/TIA 464

: Private Branch Exchange (PBX) Switching Equipment for

 

 

Voice–band Applications.

Environmental

 

 

Temperature

 

 

Operating

: 32 to 104°F (0 to 70°C)

Storage

: -40 to 158°F (-40 to 70°C)

Relative humidity

: 20 to 80%, non condensing

General Specifications

 

 

Length x width

 

13.5" x 7.7" (343 x 195.6mm)

Digital Trunk Specification

 

 

Number of T1

 

 

interfaces per DTU

:

2

Bit rate

:

1.544 Mbit/s

Signalling

: Common Channel Signalling with a 64Kbps D channel using

 

 

Q.931 protocol with proprietary extensions for mobility

 

 

management, using firmware RYS 105 650.

6-2

Specs-DCT1900/R8/mw

 

© 2000-2005

Page 82
Image 82
Nortel Networks DCT1900 manual General Specifications, Digital Trunk Specification