6.7Speech Processing Unit, SPU-S - REX-BRD0017 or ROFNB 157 16/3

Environmental

 

Temperature

 

Operating

: 32 to 104°F (0 to 70°C)

Storage

: -40 to 158°F (-40 to 70°C)

Relative humidity

: 20 to 80%, non condensing

General Specifications

 

Length x width

13.5" x 7.7" (343 x 195.6mm)

Speech Coding

 

Telephone exchange side

: 64 kbit/s PCM (A–law or μ–law, country dependent,

 

downloaded from CPU)

Base Stations side

: 32 kbit/s ADPCM

DTMF Levels

Country dependent (downloaded from CPU)

Artificial Leakage

 

 

Only if a DTU is used

: -24 dB

Dial Tone Detection

 

 

Sensitivity level

: -29 dBm

Detection time

:

800 ms

Frequencies

:

350/440 Hz

6.8Cell Link Unit, CLU - REX-BRD0014 or ROFNB 157 11/2

Environmental

 

Temperature

 

Operating

: 32 to 104°F (0 to 70°C)

Storage

: -40 to 158°F (-40 to 70°C)

Relative humidity

: 20 to 80%, non-condensing

Fusing

Power to the Base Stations is fused by two replaceable 1.0 AT fuses per Base Station.

Transport Data Rate 384 kbit/s

General Specifications

 

Length x width

13.5" x 7.7" (343 x 195.6mm)