Nortel Networks DCT1900 manual CPU2 to CPU2 More than 2 REs Figure

Models: DCT1900

1 400
Download 400 pages 50.54 Kb
Page 273
Image 273

Technical Product Manual - DCT1900

Installation Instructions, Modular Cabinet – CPU Cabling

Master

In

Out

AWS 1153

Slave 1

In

Out

Fig. 20-7 CPU2 Sync Cable for up to 2 REs

CPU2 to CPU2 - More than 2 REs (Figure 20-8)

When connecting more than 2 REs together using CPU2, it will be necessary to cut the supplied cable, AWS1153, and terminate it to a punch-down block. From the master CPU2, the outputs will be on the blue, orange, and green pairs. Cross-connect each output to the orange pair of each slave’s cable. Measure the delay of each cable, and enter the value into each slave’s configuration in nanoseconds.