Technical Product Manual - DCT1900

Maintenance, Service Messages

4.3.1 Comment to Fault Codes

zFault 17 ... 26, 28, 29, 41 CPU faults. Replacement of the CPU requires saving of its data to PC first by "System Manager-Save/Restore".If not possible any more, restore the new CPU with the most recent save file on disk (EEPROM.SAV and SPU_S.SAV).

z Fault 35, 36, 37

These faults may disappear automatically. The DTU sends a

 

message to T&M and T&M clears the fault status: L1 = AVE

 

and L2 = AVE. However, the service error message remains

 

and the general alarm as well. They must be cleared by "Clear

 

Service."

z Fault 52

Maintenance personnel must verify if the subject is operational

 

or not. It may occur that a subject is given "AVE," but not

 

working any more. If not working, reset the subject and wait for

 

new fault message. If operational then simply wait to see if the

 

fault reappears.

4-4

Maint-DCT1900/R8/mw

 

© 2000-2005

Page 376
Image 376
Nortel Networks DCT1900 manual Comment to Fault Codes, Service