Technical Product Manual - DCT1900

Installation Instructions, Modular Cabinet Connection Board (MCCB) - ROANB 101 28

PW-BP

Backplane power

PW1

PW2

PW7

PW3

PW-EXT

Fuse F1

-

+

Ground

bridge

Fuse F2

Power filter

Power filter

PW4

PW5

PW6

PW1

PW2

PW7

External power

Fig. 17–1 Power Distribution on the MCCB

Fuses

The MCCB is provided with two fast 15A fuses (see Fig. 17–1 and Fig. 17–3) to protect the external power supply from short circuit. Only use the following fuses: 7006100123, 250/15A.

DTU Cable Ground Strap Settings

The straps on the MCCB connect the cable shield of the PBX/MCCB coax cables to ground. The MCCB is delivered with all straps in the ground position (see Fig. 17–2). This setting gives the best EMC protection.

17-2

Install-DCT1900/R8/mw

 