Technical Product Manual - DCT1900

Product Specifications, System Boards

6.10Line Termination Unit, LTU - REX-BRD0007 or ROFNB 157 02/06

Compliance to Regulations and Standards

EIA-470

: USA

Environmental

 

Temperature

 

Operating

: 32 to 158°F (0 to 70°C)

Storage

: -40 to 158°F (-40 to 70°C)

Relative humidity

: 20 to 80%, non condensing

General Specifications

 

Length x width

13.5" x 7.7" (343 x 195.6mm)

Telephone Line Interface Specifications

Insulation: 1.5 kVac between line and secondary circuitry : 1 kVac between line and cabinet

DC Characteristics

 

 

Range of line current

:

10-100mA

On–hook equivalent resistance

:

> 1M between wires a and b for 50 - 250 V

AC Characteristics

 

 

On–hook impedance

: > 100 k for voice signals

 

 

> 15 k for ringing signal

Off–hook impedance

: return loss optimized against 210 + (880 // 150 nF)

Ringing Detection

 

 

Ringing voltages

:

10 - 90 Vrms

Frequency range

: > 20 Hz

Pulse Dialing

 

 

Waveform

: 60ms pulse, 40ms pulse-USA, Sweden

Selected digit N generates

: N + 1 pulse or

 

 

N pulses and digit 0 generates 10 pulses

Resistance during pulsing

:

> 5 M and < 560

Line voltage

:

limited to 100 - 14Vdc

DTMF Dialling

The DTMF signals are determined by the combination of the SPU and the SICOFI parameters.

Speech Coding

 

Method

: software selectable

AD Gain

: determined by SICOFI parameters

DA Gain

: determined by SICOFI parameters

Hybrid balance impedance

: determined by SICOFI parameters

Specs-DCT1900/R8/mw