Technical Product Manual - DCT1900

Configuration Directions, Relation between Parts

CHAPTER 6

Relation between Parts

Radio Exchange

Item

Connects

Remarks

Modular Cabinet

9 System Boards

Number of System Boards may be less due to

 

1 Connection Board

power limitations. Up to 4 cabinets can be chained.

 

An MCCB is factory mounted.

 

2 Power Supplies

 

 

 

 

 

CPU

PC, Printer, General Alarm, SMS

Only 1 per system (also with a multi–cabinet

 

and PWT air interface

system).

 

synchronization signals

CPU/SDB synchronization cables.

 

 

Note: Sync Kit required for each CPU. FPGA

 

 

must be installed.

SLU

8 calls

An SLU consists of an SPU part and a CLU part.

 

8 Base Stations

The SLU can be combined with SPU and CLU

 

boards.

 

 

 

 

The SPU part provides for 8 speech paths. The CLU

 

 

part can connect 8 Base Stations.

 

 

CLU/MDF Cables and CLU/MCCB Power cables.

 

 

Quantity depends on required traffic capacity and

 

 

GOS.

DTU-E1, CCS

60 simultaneous calls

Two 2–Mbit links, each link having 30 channels to

 

 

which Portable Telephones are assigned

 

 

dynamically. The maximum number of Portable

 

 

Telephones depends on the GOS and the traffic

 

 

capacity of the RE configuration (1 per RE)

DTU-T1, CCS

46 simultaneous calls

Two 1.544-Mbits, each link having 23 channels to

 

 

which Portable Telephones are assigned

 

 

dynamically. The maximum number of Portable

 

 

Telephones depends on the GOS and the traffic

 

 

capacity of the RE configuration (1 or 2 per RE).

DTU-E1, CAS

60 individual extensions

Two 2–Mbit links, each link having 30 channels to

 

 

which Portable Telephones are assigned on a

 

 

dedicated basis. (Max. 10 per system)

DTU-T1, CAS

48 individual extensions

Two 1.544-Mbits, each link having 24 channels to

 

 

which Portable Telephones are assigned on a

 

 

dedicated basis. (Max. 13 per system)

LTU

8 PBX lines (analog, 2 wires)

LTU/MDF Cable Set- 1 cable supports 3 LTUs . A

 

 

maximum of 272 Portable Telephones supported.

DLU

12 PBX lines (1:1 digital lines)

DLU/PBX Cable Set- 1 cable supports 2 DLUs. Each

 

 

DLU supports 12 Portable Telephones.

CLU

8 Base Stations – 2.2 miles

CLU/MDF Cables and CLU/MCCB power cables.

CLU-S

8 Base Stations – 1.2 miles

 

SPU

8 calls

The SPU provides 8 speech paths. Quantity

 

 

depends on required traffice and GOS.

MCCB

3+7 CLU or 3+7 SLU power ports

Modular Cabinet Connection Board

 

for Base Station power

 

 

PC, Printer/SMS and General

 

 

Alarm

 

SDB

1 input and 3 output PWT air

To be mounted on the bottom plate of the Modular

 

interface synchronization

Cabinet.

 

connections

 

Config-DCT1900/R8/mw

6-1

© 2000-2005

 

Page 135
Image 135
Nortel Networks DCT1900 manual Relation between Parts, Radio Exchange