Maintenance, Fault Signalling

Base Station (BS) States

 

MFG

: Base Station defective, data cable wiring fault, or download of

 

software incorrect. Also a fuse on CLU/SLU is down.

PNP

: Base Station is not connected, has lost power, has blown fuse

 

or is being downloaded.

NEW

: Base Station operational but not programmed with delay or not

 

added into the system via CSMW.

AVE

: Base Station is connected, powered and programmed.

PND

: Base Station is connected, powered and programmed but must

 

be UTAM activated. Refer to the CSMW "Installer’s Quick

 

Guide" for more information.

DLU Port States

 

NEW

: Connected but not programmed.

PNP

: Programmed but not connected.

AVE

: Connected and programmed.

MFG

: Port was connected and programmed but has encountered a

 

problem.

DTU Layer States – Layer 1 (L1)

NEW

: No physical connection to MS/PBX.

MFG

: Physical link is connected, but malfunctioning or improper

 

signalling format

AVE

: Physical connection is correct at layer 1.

DTU Layer States – Layer 2 (L2)

Only valid when layer 1 is AVE, otherwise the field of L2 remains empty.

MFG

:

No multiframe synchronization received.

AVE

:

Multiframe synchronization received.

System Synchronization States (valid with Mobility Server only)

The system synchronization states are only applicable if the CPU is a slave CPU:

MFG

: No sync signal or not yet synchronous with the sync signal at

 

the CPUs sync input connection

AVE

: Synchronous with the sync signal at the CPU sync input

 

connection.

PBX

: MS number.

LinkGroup

: MS connection number.

3.4Individual User Complaints

Individual user complaints are received from only one user or, theoretically speaking, from two or more users who are not related to each other, for example being in different areas etc.

Individual user complaints point to parts in the system that can only be accessed by that particular Portable Telephone. These parts are the Portable Telephone itself, the charger, etc. Unlike faults, for instance in Base Stations or system boards, which affect more than one user and mostly cause error reports, these types of faults cannot be detected by the system simply because of their nature. However, individual complaints are generally easy to trace.