Technical Product Manual - DCT1900

Configuration Directions, Base Station Powering

Cable

26 AWG (0.4 mm) wire size ()

24 AWG (0.5 mm) wire size ()

22 AWG (0.64 mm) wire size ()

length

 

 

 

 

 

 

 

 

 

1 pair

2 pairs

3 pairs

1 pair

2 pairs

3 pairs

1 pair

2 pairs

3 pairs

(Feet)

 

 

 

 

 

 

 

 

 

0

7.5

7.5

7.5

7.5

7.5

7.5

7.5

7.5

7.5

82

8.7

8.6

8.6

8.6

8.6

8.5

8.6

8.5

8.5

164

9.0

8.7

8.6

8.8

8.6

8.6

8.7

8.6

8.6

246

9.3

8.8

8.7

9.0

8.7

8.6

8.8

8.6

8.6

328

9.6

9.0

8.8

9.2

8.8

8.7

8.9

8.7

8.6

410

10.0

9.1

8.9

9.4

8.9

8.7

9.0

8.7

8.6

492

10.4

9.3

9.0

9.6

9.0

8.8

9.1

8.8

8.7

574

11.0

9.4

9.1

9.8

9.1

8.9

9.2

8.8

8.7

656

11.7

9.6

9.2

10.1

9.2

8.9

9.3

8.9

8.7

738

12.9

9.8

9.3

10.4

9.3

9.0

9.5

8.9

8.8

820

16.0

10.0

9.4

10.8

9.4

9.0

9.6

9.0

8.8

902

-

10.2

9.5

11.2

9.5

9.1

9.7

9.0

8.8

984

-

10.4

9.6

11.7

9.6

9.2

9.9

9.1

8.9

1066

-

10.7

9.7

12.4

9.7

9.2

10.1

9.1

8.9

1148

-

11.0

9.8

13.4

9.8

9.3

10.3

9.2

8.9

1230

-

11.3

10.0

16.0

10.0

9.4

10.5

9.3

9.0

1312

-

11.7

10.1

-

10.1

9.4

10.7

9.3

9.0

1476

-

12.9

10.4

-

10.4

9.6

11.2

9.5

9.1

1640

-

16.0

10.8

-

10.8

9.7

11.9

9.6

9.2

1804

-

-

11.2

-

11.2

9.9

12.8

9.7

9.2

1968

-

-

11.7

-

11.7

10.1

14.6

9.9

9.3

2132

-

-

12.4

-

12.4

10.3

-

10.1

9.4

2296

-

-

13.4

-

13.4

10.5

-

10.3

9.5

2460

-

-

16.0

-

16.0

10.8

-

10.5

9.6

2624

-

-

-

-

-

11.0

-

10.7

9.7

2788

-

-

-

-

-

11.4

-

10.9

9.8

2952

-

-

-

-

-

11.7

-

11.2

9.9

3116

-

-

-

-

-

12.2

-

11.5

10.0

3280

-

-

-

-

-

12.7

-

11.9

10.1

3608

-

-

-

-

-

14.6

-

12.8

10.4

3936

-

-

-

-

-

-

-

14.6

10.7

4264

-

-

-

-

-

-

-

-

11.0

4592

-

-

-

-

-

-

-

-

11.4

4920

-

-

-

-

-

-

-

-

11.9

5248

-

-

-

-

-

-

-

-

12.4

5576

-

-

-

-

-

-

-

-

13.2

5904

-

-

-

-

-

-

-

-

14.6

Table 4–4 Power Consumption (Watts) of Base Stations and Cabling when Powered with 48V