Technical Product Manual - DCT1900

Configuration Directions, Traffic Capacity of the System

As a RE can handle only as many simultaneous calls as the number of available speech circuits while the number of Portable Telephones in the respective coverage area can be as many as 600, a lack of speech circuits may occur in some occasions. To limit these occurrences, take into account the number of regular (home) Portable Telephone users plus the maximum number of visiting Portable Telephone users at a certain time while determining the required traffic capacity. Table 5–2 shows what Erlang values mean in call–minutes for a Portable Telephone.

mErlang

Minutes per hour

mErlang

50

3

250

100

6

300

150

9

500

200

12

750

Minutes per hour

15

18

30

45

Table 5–2 Erlang Values Expressed in Call–Minutes

Example: A customer ordering a system that can handle 55 Portable Telephones (local users and visiting users), generating 200 mE each in average, requires a system with a traffic capacity of 11 E. With an accepted GOS of 0.5% the number of SPUs/SLUs is found as follows:

The total traffic is 11 E. In the column of 0.5% GOS, the next higher value of 11 E is 14.2 E, resulting in 3 SPUs/SLUs.

So, the system should be equipped with 3 SPUs/SLUs, offering the client 14.2 E instead of 11. This means that the system has an over–capacity 3.2 E, which allows expansion of the system with 16 Portable Telephones without reducing the GOS or the need of more SPUs or SLUs.

According to Table 5–1 60 circuits with an accepted GOS of 0.5% result in a maximum traffic capacity of the system of 44.8 E. When each Portable Telephone generates 150 mE in average, the system has a capacity of serving approximately 300 Portable Telephones.

5.2Traffic Capacity of the Base Stations

The total traffic that is being generated by all Portable Telephones (visiting Portable Telephones included) of the system should be in accordance with the capacity of the cordless network as well. A Base Station, having 8 channels available, has an Erlang value of 2.7 with a GOS of 0.5%. This value can be read from the Table 5-1. This means that each Base Station can serve 18 Portable Telephones, assuming that Portable Telephones generate 150 mE each during busy hours (13.5 Portable Telephones if 200 mE each).

Example: Suppose that in the building of the customer in the example in paragraph 5.1, full coverage can be achieved by 4 Base Stations. This means that all Portable Telephones generate together 55 x 0.200 = 11 E, while the Base Stations traffic capacity is only 4 x 2.7 = 10.8 Erlang. This is too little. This discrepancy can be solved by adding another Base Station near the busiest part of the building.

From an average point of view, the total capacity offered by the cordless network is generally more than sufficient. In certain places, traffic demands may vary such that locally the network is often blocking, or has a lower GOS than required. For instance, a purchasing department may easily generate 300 mE per Portable Telephone during a busy hour, with 6 persons giving a very high

5-2

Config-DCT1900/R8/mw

 

© 2000-2005

Page 132
Image 132
Nortel Networks DCT1900 manual Traffic Capacity of the Base Stations, Erlang Values Expressed in Call-Minutes