Technical Product Manual - DCT1900

Configuration Directions, Base Station Powering

Cable

26 AWG (0.4 mm) wire size ()

24 AWG (0.5 mm) wire size ()

22 AWG (0.64 mm) wire size ()

length

 

 

 

 

 

 

 

 

 

1 pair

2 pairs

3 pairs

1 pair

2 pairs

3 pairs

1 pair

2 pairs

3 pairs

(Feet)

 

 

 

 

 

 

 

 

 

0

7.5

7.5

7.5

7.5

7.5

7.5

7.5

7.5

7.5

82

8.8

8.6

8.6

8.7

8.6

8.6

8.6

8.6

8.5

164

9.1

8.8

8.7

8.9

8.7

8.6

8.7

8.6

8.6

246

9.5

9.0

8.8

9.1

8.8

8.7

8.9

8.7

8.6

328

10.0

9.1

8.9

9.4

8.9

8.8

9.0

8.7

8.7

410

10.7

9.3

9.0

9.7

9.0

8.8

9.2

8.8

8.7

492

11.6

9.5

9.1

10.0

9.1

8.9

9.3

8.9

8.7

574

13.1

9.8

9.3

10.5

9.3

9.0

9.5

8.9

8.8

656

-

10.0

9.4

10.9

9.4

9.1

9.7

9.0

8.8

738

-

10.3

9.5

11.6

9.5

9.1

9.9

9.1

8.9

820

-

10.7

9.7

12.5

9.7

9.2

10.1

9.2

8.9

902

-

11.1

9.9

14.0

9.9

9.3

10.3

9.2

9.0

984

-

11.6

10.0

-

10.0

9.4

10.6

9.3

9.0

1066

-

12.2

10.2

-

10.2

9.5

10.9

9.4

9.1

1148

-

13.1

10.5

-

10.5

9.6

11.3

9.5

9.1

1230

-

14.7

10.7

-

10.7

9.7

11.7

9.6

9.2

1312

-

-

10.9

-

10.9

9.8

12.2

9.7

9.2

1476

-

-

11.6

-

11.6

10.0

14.0

9.9

9.3

1640

-

-

12.5

-

12.5

10.3

-

10.1

9.4

1804

-

-

14.0

-

14.0

10.6

-

10.3

9.5

1968

-

-

-

-

-

10.9

-

10.6

9.7

2132

-

-

-

-

-

11.3

-

10.9

9.8

2296

-

-

-

-

-

11.8

-

11.3

9.9

2460

-

-

-

-

-

12.5

-

11.7

10.1

2624

-

-

-

-

-

13.3

-

12.2

10.2

2788

-

-

-

-

-

15.0

-

12.9

10.4

2952

-

-

-

-

-

-

-

14.0

10.6

3116

-

-

-

-

-

-

-

-

10.8

3280

-

-

-

-

-

-

-

-

11.0

3444

-

-

-

-

-

-

-

-

11.3

3608

-

-

-

-

-

-

-

-

11.6

3772

-

-

-

-

-

-

-

-

11.9

3936

-

-

-

-

-

-

-

-

12.2

4100

-

-

-

-

-

-

-

-

12.7

4264

-

-

-

-

-

-

-

-

13.2

4428

-

-

-

-

-

-

-

-

14.0

4592

-

-

-

-

-

-

-

-

15.4

Table 4–3 Power Consumption (Watts) of Base Stations and Cabling when Powered with 42V

4-6

Config-DCT1900/R8/mw

 

© 2000-2005

Page 126
Image 126