Technical Product Manual - DCT1900

Maintenance, Service Messages

Fault

Service

Fault

Description

Code

class

Threshold

 

1

2

5

Unexpected message/primitive. Message received but not within specified time

2

1

99

Board/CPU communication error or time out. Message corrupted or not received

3

2

99

Threshold fault counter or Reset counter exceeded

4

3

1

Board controller ROM error

5

3

1

Board controller RAM error

6

3

2

Internal loopback error

7

2

5

Peripheral state error

 

 

 

- State of peripheral differs from state listed in CPU data base

8

1

30

Base Station not present

 

 

 

- wiring fault or power lost

9

3

2

Peripheral ROM error

10

3

2

Peripheral RAM error

11

2

99

Peripheral status unknown. Two simultaneous faults: status can not be obtained

12/13

2

99

Board status unknown. No communication with board: status can not be obtained

14

2

5

Peripheral communication error or time out. Message corrupted or not received

15

2

2

Board signalling link was cut. When a board is not polled, it resets itself and after

 

 

 

communication has recovered it sends this message to CPU

16

1

10

Board controller poll response error

17

3

99

CPU main processor RAM error

18

3

99

CPU main processor ROM error

19

3

99

CPU EEPROM error

20

2

1

CPU real time clock test failed

21

3

2

CPU–poll processor (8031) RAM error

22

3

2

CPU–poll processor (8031) ROM error

23

1

2

CPU–poll processor communication error

26

2

5

CPU internal buffer overflow

27

2

99

Board controller watchdog reset

28

1

2

HSCX error. Serial communication controller on CPU of signalling highway

29

3

99

Signalling highway down. No communication between CPU and all other boards

33

1

1

Initialization procedure not successful. Due to e.g.: no communication with board

34

1

99

Portable Telephone related circuit not present. LTC or DTU–channel

35

2

30

Layer 1 fault at link with PBX: no physical connection or DTU error, L1 = MFG

 

 

 

- this fault may disappear automatically. CPU will set L1 and L2 to AVE again. The

 

 

 

service error message and general alarm remain and must be cleared manually

36

2

30

Layer 1 fault at link with PBX: Error in trunk unit of remote PBX (PBX did detect the

 

 

 

error), L1 = MFG - see note at fault 35

37

1

4

Layer 2 fault at link with PBX: No multiframe synchronization, L1=AVE, L2=MFG

 

 

 

- see note at fault 35

38

1

2

DTU or DLU hardware failure

39

1

99

PC communication error

 

 

 

- when statistics runs, logging is stopped. Statistics must be set "ON" again.

40

3

3

SPU parameters on board have wrong checksum

41

2

99

System Sync Delay hardware out of lock

50

1

*

Minimum configuration error, see Chapter 2, Paragrah 2.4.1, "Backplane Reset"

51

2

*

Subject is unreliable. Fault is not continuously present

52

2

*

Subject could not be tested after maintenance action due to a coincidence

 

 

 

- Subject must be verified if operational. It may be ‘AVE’ but not working. Reset subject

*Not handled by tam_dbas, so threshold is effectively infinite

Table 4–1 Fault Codes in Service Table

Maint-DCT1900/R8/mw

4-3

© 2000-2005

 

Page 375
Image 375
Nortel Networks DCT1900 manual Fault Codes in Service Table