Technical Product Manual - DCT1900

Installation Instructions, Modular Cabinet – LTU Cabling

Connector

Cable Pair-In

Wire Color

25 Pair

Signal Name

 

 

 

Connector Pin

 

5

7-5

Red

44

Analog Channel - 19T

5

7-6

Orange

19

Analog Channel -19R

5

8-1

Red

45

Analog Channel - 20T

5

8-2

Green

20

Analog Channel - 20R

6

9-5

Red

46

Analog Channel - 21T

6

9-6

Brown

21

Analog Channel - 21R

6

10-1

Red

47

Analog Channel - 22T

6

10-2

Gray

22

Analog Channel - 22R

6

11-5

Black

48

Analog Channel - 23T

6

11-6

Blue

23

Analog Channel - 23R

6

12-1

Black

49

Analog Channel -24T

6

12-2

Orange

24

Analog Channel -24R

Table 23-1 LTU to 66 Block Cabling (cont.)

Analog channel 1 tip/ring will appear at the top of the 66 Block. Analog channel 24 tip/ring will appear on the second to the last pair of the punch down clips at the bottom of the Block. Pair 25 is not used and is not connected.

Note:

To meet the EMC requirements, the cable should never be cut to a length shorter than 8.2 ft.

Signalling Ground for LTU when using Earth Signalling for Recall

The signalling ground is only applicable when earth signalling is used instead of timed break signalling. The MCCB connect the signalling ground from the PBX to maximum of 7 LTUs.

1.Connect the PBX signalling ground from the MDF to the PBX screw connector on the MCCB.

2.If more Modular Cabinets are used in a system, chain the PBX connectors.

3.Connect an LTU/MCCB ground cable (TSRNB 101 035) to the LTU1 connector on the MCCB.

4.Connect the other end of the LTU/MCCB ground cable to the LTU ground connector on the furthest left LTU (see Fig. 23-2).

23-4

Install-DCT1900/R8/mw

 

© 2000-2005

Page 296