Nortel Networks DCT1900 manual Line Termination Unit , LTU2 REX-BRD0019A

Models: DCT1900

1 400
Download 400 pages 50.54 Kb
Page 188
Image 188

Technical Product Manual - DCT1900

Product Specifications, System Boards

6.11Line Termination Unit , LTU2 - REX-BRD0019A

Compliance to Regulations and Standards

EIA-470

: USA

Environmental

 

Temperature

 

Operating

: 32 to 158°F (0 to 70°C)

Storage

: -40 to 158°F (-40 to 70°C)

Relative humidity

: 20 to 80%, non condensing

General Specifications

 

Length x width

13.5" x 7.6" x .8" (344 x 192 x 20 mm)

Weight

.95 lb (430 grams) (excluding packaging)

Telephone Line Interface Specifications

Insulation: 1.5 kVac between line and secondary circuitry : 1 kVac between line and cabinet

DC Characteristics

 

 

 

 

 

Range of line current

:

60 mA max.

 

 

 

On–hook equivalent resistance

:

> 9 M between wires a and b for 200 Vdc

Resistance to earth (in quiescent

 

 

 

 

and loop state)

:

1 G between wires a/b and E-wire for up to 250 Vdc

AC Characteristics

 

 

 

 

 

On–hook impedance

: Software programmable 600

or complex

Off–hook impedance

: See ’Ringing Detection’

 

 

 

Return Loss

:

15 dB min.

 

 

 

Relative levels

:

Software programmable

 

 

 

Input (AD loss) range

:

6 to -11dBr against 270

+ (750 // 150 nF)

Output (DA loss) range

:

12 to -4.5 dBr against 270

+ (750

// 150 nF)

Balancing impedance

:

Software programmable; 600

, 900

or complex

Longitudinal conversion loss

:

60 dB min. between 50 Hz and 4 KHz

 

Ringing Detection

 

 

 

 

 

Ringing voltages

:

10 k min. between 24 to 90 Vrms, 25 to 50 Hz

Impedance for voice signals

:

100 k min. at AC voltages up to 2 V (peak),300 Hz to 3400 Hz

Capacity

:

1 μF +/- 5%

 

 

 

Ringing voltages

: 24 to 120 Vrms

 

 

 

Insensitive to signals

:

17 Vrms max.

 

 

 

Frequency range

: Software programmable between 16 and 64 Hz

Pulse Dialing

 

 

 

 

 

Make/break period

: Software programmable between 0 to 255 ms

Selected digit N generates

: N pulses and digit 0 generates either 10 pulses (default)

Line Voltage during pulsing

:

Limited to 240 Vdc

 

 

 

6-8

Specs-DCT1900/R8/mw

 

© 2000-2005

Page 188
Image 188