CHAPTER 6 - RAID Controller
SPI-8450-LLVA 49
6.2.8 Viewing Controller Settings
The Controller Configuration <6> menu selection allows you to enable or disable the Raid
controller BIOS from halting (the default) if it detects an error on boot up. You may also view
the system resources (Interrupt and I/O port address) of FastTrak’s data channels.
FastBuild (tm) Utility 1.xx (c) 1996-2001 Promise Technology, Inc.
[ Adapter Configuration - Options ]
Halt On Error: Enable
[ System Resources Configuration ]
Channel 1 (IDE1) Interrupt : A I/O Port : FFF0
Channel 2 (IDE2) Interrupt : A I/O Port : FFA8
[ Keys Available ]
[←, →, Space] Change Option [ESC] Exit
Halting Raid controller BIOS on Bootup Errors
The [Adapter Configuration – Options] section allows you to enable or disable Raid controller
to Halt operation at the BIOS startup screen should an error be detected. This is the only option
that can be changed on this screen.
Viewing Raid Controller System Resource
The [System Resources Configurations] section of this submenu displays the PCI slot interrupt
and port address used by the Raid controller. The resources used are determined by the SPI-
8450-LLVA PCI PnP BIOS for the PCI device resides.
In the rare case that there is a resource conflict, refer to the SPI-8450-LLVA BIOS
documentation on changes on resources allocated to the Raid Controller.