Rebuild Wizard Step 2 confirms the Target or “Rebuild” disk by Array # and drive ID.
Click Finish button to initiate physical Rebuild, Back button to review Step 2, or Cancel button
to Stop. A final confirmation window appears as below:
Click “Yes” to initiate Rebuild. To cancel this option, click the No button.
WARNING: Once initiated, Array Rebuild can NOT be halted in order to prevent data errors.
NOTE: During Array Rebuild, users may continue to access the array and perform normal PC
functions however the array will NOT provide data redundancy until Rebuild is
completed. If you choose to continue using the PC during rebuild, system
performance will be slightly degraded and the process will take longer.
Once Array Rebuild has begun, users are returned to the FastCheck™ Monitoring window. A
progress bar showing the rebuild progress in percentage will appear at the bottom of the
FastCheck™ Monitoring window.
NOTE: When a “spare” unassigned drive is present on the FastTrak100-Lite, a rebuild will
automatically be performed from the remaining working drive.