FUNCTION KEYS

The five keys located to the right of the display are the function keys. They are:

io._o_ -- Turns the display "On" or "Off"

_j --Selects the Bevel Angle display

i-_. _j--Selects the Blade Tension display

E

_p_- Selects the Blade Speed display

-- Sets the Bevel Angle to Zero

NOTE: In order to extend battery life the display will shut off approximately five (5) minutes after the last key was pressed.

USING THE ELECTRONIC INDICATOR SYSTEM

1.Setting the Bevel Angle Reference Point. Whenever the battery is installed or a new zero

point is desired, it is necessary to set the zero reference. Normally the zero reference is set with the blade vertical to the table. When the blade is

in the desired position for the zero point do the following.

a. Press theIONIOFI¢key if display is off.

b. Press the _E._--_ key, then the ._,s_j key. c. Display should read: Fv 'U.U-'i

2. Selecting Blade Tension

n

a. Press the IoF_.IQFkey! if display is off.

b. Press the _ T,.

key.

c. The digital display will show one of seven tension settings. Turn the tension knob until the correct read-out appears for the blade or sanding belt you have selected.

Read-out

i Indicates correct tension for:

L

Loose - no

tension

S

Sanding

Belt

.125

1/8"

blade

.250

1/4"

blade

.375

3/8"

blade

.500

1/2"

blade

E

Overtensioned

3. Blade Speed

The digital display will read out one of two starting speeds, depending on where the motor belt is positioned on the pulleys. The two starting speeds are 3000 FPM and 1500 FPM. The speed ranges for each starting point are:

3000

1500

2800

1400

*2600

'1300

2400

1200

2200

1100

2OOO

1000

The band saw motor wilt stall if the blade speed drops two steps* below operating speed,

NOTE: It is important to maintain maximum cutting efficiency by keeping the blade speed as fast as possible. Do not feed the work piece too rapidly, tt will overload the motor and stall the blade,

25

Page 25
Image 25
Craftsman 113.248510 Function Keys, Using the Electronic Indicator System, Read-out Indicates correct tension for, 3000