Cuno 111405-1 C O N T R O L C E N T E R, E L E C T R O N I C, Unit Power, Temperature Adjustments

Models: 111405-1

1 80
Download 80 pages 12.13 Kb
Page 6
Image 6
E L E C T R O N I C

E L E C T R O N I C

C O N T R O L C E N T E R

The electronic control center is located at the top of the fresh food compartment.

NOTE:

Allow the refrigerator to run for 8-12 hours before loading. This ensures appropriate temperatures for food storage.

NOTE:

Thermometers placed in the refriger- ator may record a temperature slightly above or below the displayed tempera- ture. This is normal as the displayed temperature is an average.

Press the Door Alarm pad again to deactivate.

When the alarm has sounded, close door to reset.

OR

Press the Door Alarm pad to deacti- vate. Press again to reactivate, if desired.

UNIT POWER

Touch this pad to start or stop cooling and turn off the lights in both the fresh food and freezer compartments. This pad DOES NOT shut off power to the refrigerator.

To turn off all power to the refrigerator, turn the Main Power switch OFF or “O” (see page 4).

IMPORTANT:

Turn off all power to the refrigerator at the main power switch whenever changing light bulbs, cleaning or serv- icing this refrigerator.

INITIAL TEMPERATURE SETTINGS

Temperatures are preset at 37° F (3° C) in the fresh food compartment and 0° (-18° C) in the freezer compartment. The display will show the average compartment tem- peratures, based on several measurement points within the compartment.

NOTE:

Temperatures displayed may vary from set point due to door openings or during defrost.

TEMPERATURE

ADJUSTMENTS

Allow the temperature to stabilize for 24 hours after loading the refrigerator before making any temperature adjust- ments.

The first touch of the up or down arrow shows the current temperature setpoint.

Subsequent touches of the C O N T R O L C E N T E R pad raise the temperature set point or

the UNIT POWER pad lowers the temperature set point.

The display will show the new setpoint for approximately three seconds, then return to the actual temperature currently within that compartment.

Limit temperature changes to one degree at a time. Allow the new tem- peratures to stabilize for 24 hours before making a new temperature adjustment.

DOOR ALARM

The Door Alarm will alert you when one of

the doors has been left

open for 10 continuous minutes. When this hap-

pens, the compartment light will go out and a chime will sound every few seconds until the door is closed or the Door Alarm pad is pressed to deactivate the function.

Press the Door Alarm pad to activate. A chime will sound and ON will illumi- nate.

WATER FILTER

WORKING is illuminated when

a water filter has

been installed. It will not illumi- nate when the

filter bypass is in

place (see page 13 for information on installation of the water filter or bypass).

ORDER will illuminate when 90 per- cent of the volume of water for which the filter is rated has passed through the filter.

OR

Eleven months have elapsed since the filter has been installed.

REPLACE illuminates when the rated volume of water has passed through the filter or 12 months have elapsed since the filter was installed. A new filter should be installed immediately when REPLACE is illuminated.

When the new filter is installed, the WORKING light will reilluminate. See page 13.

NOTE:

Power to the refrigerator must be ON when the filter is changed for the water filter monitoring system to reset and change back to the “WORKING” indicator.