CY14B101K
Software Controlled STORE/RECALL Cycles [21, 22]
Parameter | Alt. | Description | 25 ns | 35 ns | 45 ns | Unit | |||
Parameter  | Min | Max | Min  | Max  | Min  | Max  | |||
tRC  | tAVAV  | STORE/RECALL Initiation Cycle  | 25  | 
  | 35  | 
  | 45  | 
  | ns  | 
  | 
  | Time  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
tSA  | tAVEL  | Address Setup Time  | 0  | 
  | 0  | 
  | 0  | 
  | ns  | 
tCW  | tELEH  | Clock Pulse Width  | 20  | 
  | 25  | 
  | 30  | 
  | ns  | 
tHA  | tEHAX  | Address Hold Time  | 1  | 
  | 1  | 
  | 1  | 
  | ns  | 
tRECALL  | 
  | RECALL Duration | 
  | 170 | 
  | 170  | 
  | 170  | μs  | 
Figure 13. CE Controlled Software STORE/RECALL Cycle [22]
ADDRESS
CE
OE
tRC
ADDRESS # 1
tSA  | 
  | 
  | 
  | 
  | tSCE  | 
  | 
  | ||||
  | 
  | 
  | 
  | 
  | 
  | 
tHA
tRC
ADDRESS # 6
tSTORE / tRECALL
DQ (DATA)
ADDRESS ![]()
CE
OE
tRC
ADDRESS # 1
tSA  | 
  | 
  | 
  | 
  | tSCE  | 
  | 
  | ||||
  | 
  | 
  | 
  | 
  | 
  | 
 tHA
tRC
ADDRESS # 6
tSTORE / tRECALL
DQ (DATA)  | DATA VALID  | 
DATA VALID  | HIGH IMPEDANCE  | 
  | 
Notes
21.The software sequence is clocked with CE controlled or OE controlled READs.
22.The six consecutive addresses are read in the order listed in the Table 2 on page 6. WE is HIGH during all six consecutive cycles.
Document Number:   | Page 20 of 28  | 