Software Controlled STORE/RECALL Cycles [21, 22]
Parameter | Alt. | Description | 25 ns | 35 ns | 45 ns | Unit | |||
Parameter | Min | Max | Min | Max | Min | Max | |||
tRC | tAVAV | STORE/RECALL Initiation Cycle | 25 |
| 35 |
| 45 |
| ns |
|
| Time |
|
|
|
|
|
|
|
tSA | tAVEL | Address Setup Time | 0 |
| 0 |
| 0 |
| ns |
tCW | tELEH | Clock Pulse Width | 20 |
| 25 |
| 30 |
| ns |
tHA | tEHAX | Address Hold Time | 1 |
| 1 |
| 1 |
| ns |
tRECALL |
| RECALL Duration |
| 170 |
| 170 |
| 170 | μs |
Figure 13. CE Controlled Software STORE/RECALL Cycle [22]
ADDRESS
CE
OE
tRC
ADDRESS # 1
tSA |
|
|
|
| tSCE |
|
| ||||
|
|
|
|
|
|
tHA
tRC
ADDRESS # 6
tSTORE / tRECALL
DQ (DATA)
ADDRESS
CE
OE
tRC
ADDRESS # 1
tSA |
|
|
|
| tSCE |
|
| ||||
|
|
|
|
|
|
tHA
tRC
ADDRESS # 6
tSTORE / tRECALL
DQ (DATA) | DATA VALID |
DATA VALID | HIGH IMPEDANCE |
|
Notes
21.The software sequence is clocked with CE controlled or OE controlled READs.
22.The six consecutive addresses are read in the order listed in the Table 2 on page 6. WE is HIGH during all six consecutive cycles.
Document Number: | Page 20 of 28 |